Matsumoto Tomoyuki, Tsumura Nobuhiro, Kurosaka Masahiro, Muratsu Hirotsugu, Yoshiya Shinichi, Kuroda Ryosuke
Dept of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Orthopedics. 2006 Dec;29(12):1115-20. doi: 10.3928/01477447-20061201-04.
Thirty posterior stabilized total knee prostheses implanted using a computed tomography-free navigation system were compared to a control group of 30 matched total knee prostheses of the same type implanted via a classical, surgeon-controlled technique. The accuracy of the implantations in relation to the mechanical axis in the navigation group was superior to that of the manual group. Early two-year clinical results including range of motion and Knee Society Clinical Rating Score were equally good compared to the manual group. However, potential long-term outcome and functional improvement require further investigation.