Suppr超能文献

长时间使用电击武器对人类志愿者呼吸功能的影响。

Respiratory effect of prolonged electrical weapon application on human volunteers.

作者信息

Ho Jeffrey D, Dawes Donald M, Bultman Laura L, Thacker Jenny L, Skinner Lisa D, Bahr Jennifer M, Johnson Mark A, Miner James R

机构信息

Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, MN, USA.

出版信息

Acad Emerg Med. 2007 Mar;14(3):197-201. doi: 10.1197/j.aem.2006.11.016. Epub 2007 Feb 5.

Abstract

BACKGROUND

Conducted electrical weapons (CEWs) are used by law enforcement to subdue combative subjects. Occasionally, subjects will die after a CEW has been used on them. It is theorized that CEWs may contribute to these deaths by impairing respiration.

OBJECTIVES

To examine the respiratory effects of CEWs.

METHODS

Human volunteers received a 15-second application of electrical current from a CEW while wearing a respiratory measurement device. Common respiratory parameters were collected before, during, and after exposure. Health histories and demographic information were also collected.

RESULTS

Fifty-two subjects were analyzed. Thirty-four underwent a 15-second continuous exposure, and 18 underwent three 5-second burst exposures. In the continuous application group, the baseline mean tidal volume of 1.1 L increased to 1.8 L during application, the baseline end-tidal CO2 level went from 40.5 mm Hg to 37.3 mm Hg after exposure, the baseline end-tidal oxygen level went from 118.7 mm Hg to 121.3 mm Hg after exposure, and the baseline respiratory rate went from 15.9 breaths/min to 16.4 breaths/min after exposure. In the 5-second burst group, the baseline mean tidal volume increased to 1.85 L during application, the baseline end-tidal CO2 level went from 40.9 mm Hg to 39.1 mm Hg after exposure, the baseline end-tidal oxygen level went from 123.1 mm Hg to 127.0 mm Hg after exposure, and the baseline respiratory rate went from 13.8 breaths/min to 14.6 breaths/min after exposure.

CONCLUSIONS

Prolonged CEW application did not impair respiratory parameters in this population of volunteers. Further study is recommended to validate these findings in other populations.

摘要

背景

执法部门使用导电电子武器(CEW)制服具有攻击性的对象。偶尔,在对对象使用CEW后,他们会死亡。据推测,CEW可能通过损害呼吸功能导致这些死亡。

目的

研究CEW对呼吸的影响。

方法

人类志愿者佩戴呼吸测量设备,接受来自CEW的15秒电流刺激。在暴露前、暴露期间和暴露后收集常见的呼吸参数。还收集了健康史和人口统计学信息。

结果

对52名受试者进行了分析。34人接受了15秒的连续暴露,18人接受了三次5秒的脉冲暴露。在连续暴露组中,应用期间基线平均潮气量从1.1升增加到1.8升,暴露后基线呼气末二氧化碳水平从40.5毫米汞柱降至37.3毫米汞柱,暴露后基线呼气末氧水平从118.7毫米汞柱升至121.3毫米汞柱,暴露后基线呼吸频率从15.9次/分钟升至16.4次/分钟。在5秒脉冲组中,应用期间基线平均潮气量增加到1.85升,暴露后基线呼气末二氧化碳水平从40.9毫米汞柱降至39.1毫米汞柱,暴露后基线呼气末氧水平从123.1毫米汞柱升至127.0毫米汞柱,暴露后基线呼吸频率从13.8次/分钟升至14.6次/分钟。

结论

在这群志愿者中,长时间使用CEW并未损害呼吸参数。建议进一步研究以在其他人群中验证这些发现。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验