Nagaraja Prem Anand, Shetty Devi
Narayana Hrudayalaya, Bommasandra Industrial Area, Anekal Taluk, Bangalore, Karnataka, India.
ANZ J Surg. 2007 Jan-Feb;77(1-2):80-3. doi: 10.1111/j.1445-2197.2006.03560.x.
Surgical suture packs are opened (and external packaging removed) on the operating table prior to surgery. Some of these suture packs may not be used in the surgery for reasons of inappropriateness or change in the surgical technique or following accidental contact with a non-sterile surface. These unused sutures with their foil packs still unopened are sometimes re-sterilized using ethylene oxide to allow for reuse. This re-sterilization of unopened suture packs can be contentious, due to legislation and health regulations in developed countries. The purpose of the present paper was to measure the effect of such repeated gas sterilization on sutures.
The knot tensile strength was measured for new sterile sutures and ethylene oxide re-sterilized sutures. The tests were conducted on two available brands of sutures, including both absorbable and non-absorbable synthetic sutures.
No statistically significant difference was observed in the tensile strengths between the two sets of sutures, before and after re-sterilization. Some foil packs showed slight crimping after re-sterilization, but remained intact. No humidity was observed inside the foil packs.
Re-sterilization of unused suture foil packs can be carried out without loss of tensile strength.
手术缝线包在手术前于手术台上打开(并去除外包装)。其中一些缝线包可能因不合适、手术技术改变或意外接触到非无菌表面而未在手术中使用。这些未使用的缝线及其铝箔包装仍未打开,有时会使用环氧乙烷进行再次灭菌以便重复使用。由于发达国家的立法和健康法规,未打开的缝线包的这种再次灭菌可能存在争议。本文的目的是测量这种重复气体灭菌对缝线的影响。
测量新的无菌缝线和环氧乙烷再次灭菌的缝线的结拉伸强度。对两种可用品牌的缝线进行了测试,包括可吸收和不可吸收的合成缝线。
再次灭菌前后两组缝线的拉伸强度没有观察到统计学上的显著差异。一些铝箔包装在再次灭菌后显示出轻微卷曲,但仍保持完整。铝箔包装内未观察到湿度。
未使用的缝线铝箔包可以进行再次灭菌而不会损失拉伸强度。