Sorsdahl Anne Brit, Moe-Nilssen Rolf, Strand Liv Inger
Department of Public Health and Primary Health Care, Section for Physiotherapy Science, University of Bergen, N-5020, Bergen, Norway.
Gait Posture. 2008 Jan;27(1):43-50. doi: 10.1016/j.gaitpost.2007.01.001. Epub 2007 Feb 14.
The purpose of this study was to examine test-retest reliability of seven selected temporal and spatial gait parameters and asymmetry measures in children with cerebral palsy.
Seventeen children with CP between 3 and 13 years of age walked at three different speeds across an electronic walkway of 5.2m. The tests were repeated after approximately 25 min. The scores were normalized to a walking speed of 1.1m/s to avoid the confounding effect of gait speed on speed dependent gait parameters. Intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) with 95% confidence intervals, within-subject standard deviation (S(w)) and smallest detectable difference (SDD) were calculated.
The relative reliability of cadence, step length, stride length and single stance time was high to excellent (ICC(1,1) between 0.73 and 0.95), while it was poor for step width (ICC(1,1)=0.27 and 0.35). The relative reliability for two calculated asymmetry measures were high for the step length index (ICC(1,1)=0.82) and moderate for the single stance time index (ICC(1,1)=0.49). The absolute reliability values for all gait parameters are reported.
Five of seven gait parameters measured by an electronic walkway and normalized to a common walking speed, appear to be highly repeatable in a short-term time span in children with CP who were able to walk without assistive walking devices, provided sufficient cognitive function.
本研究旨在检验七项选定的时间和空间步态参数以及脑瘫患儿的不对称性测量指标的重测信度。
17名年龄在3至13岁之间的脑瘫患儿以三种不同速度走过一条5.2米的电子步道。约25分钟后重复测试。为避免步态速度对速度依赖性步态参数的混杂影响,将分数标准化为1.1米/秒的步行速度。计算了组内相关系数(ICC(1,1)和ICC(3,1))及其95%置信区间、受试者内标准差(S(w))和最小可检测差异(SDD)。
步频、步长、步幅和单支撑时间的相对信度较高至优秀(ICC(1,1)在0.73至0.95之间),而步宽的相对信度较差(ICC(1,1)=0.27和0.35)。两个计算出的不对称性测量指标的相对信度,步长指数较高(ICC(1,1)=0.82),单支撑时间指数中等(ICC(1,1)=0.49)。报告了所有步态参数的绝对信度值。
对于能够在无辅助步行设备的情况下行走且具备足够认知功能的脑瘫患儿,通过电子步道测量并标准化为共同步行速度的七项步态参数中的五项,在短期内似乎具有高度可重复性。