Mackey A H, Stott N S, Walt S E
Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.
Gait Posture. 2008 Nov;28(4):634-9. doi: 10.1016/j.gaitpost.2008.04.012. Epub 2008 Jun 5.
This study evaluated within- and between-session reliability and validity of temporal-spatial gait parameters derived from the intelligent device for energy expenditure and activity (IDEEA) activity monitor (Minisun, Fresno, CA) in subjects with cerebral palsy, using three-dimensional gait analysis (3-DGA) as the criterion standard. Twenty-five subjects with cerebral palsy (mean age 14.1 years, range 8-23) and 30 control subjects (mean age 14.2 years, range 7-24) completed two 3-DGA, 1 week apart with simultaneous IDEEA data collection. The IDEEA had lower within-session reliability than the 3-DGA for both groups, indicated by greater measurement errors and wider repeatability values for all temporal-spatial parameters. Between-session reliability of 3-DGA was high for both groups with intra-class correlation coefficients (ICC) >0.80. The IDEEA monitor showed high between-session reliability for control subjects (ICC 0.71-0.89), but lower reliability in subjects with cerebral palsy, particularly for walking velocity and stride length (ICC 0.53 and 0.62, respectively). Validity comparison between IDEEA and 3-DGA measures using Bland Altman 95% limits of agreement showed a measurement bias, with the IDEEA over-estimating step and stride length and underestimating cadence in both subject groups compared to 3-DGA. The 95% limits of agreement were smaller in controls (step +/-0.20 m; stride +/-0.27 m; walking velocity +/-0.28 m/s) than in subjects with cerebral palsy (step +/-0.36 m; stride +/-0.37 m; velocity +/-0.58 m/s). Modifications may be necessary to improve the reliability and validity of the IDEEA in children, particularly for use in neurological conditions.
本研究以三维步态分析(3-DGA)作为标准,评估了用于能量消耗和活动的智能设备(IDEEA)活动监测仪(Minisun,弗雷斯诺,加利福尼亚州)所获取的时空步态参数在脑瘫受试者中的组内和组间可靠性及有效性。25名脑瘫受试者(平均年龄14.1岁,范围8 - 23岁)和30名对照受试者(平均年龄14.2岁,范围7 - 24岁)完成了两次3-DGA测试,间隔1周,同时收集IDEEA数据。对于两组而言,IDEEA的组内可靠性均低于3-DGA,所有时空参数的测量误差更大且重复性值更宽,这表明了这一点。两组3-DGA的组间可靠性都很高,组内相关系数(ICC)>0.80。IDEEA监测仪显示对照受试者的组间可靠性较高(ICC为0.71 - 0.89),但在脑瘫受试者中的可靠性较低,尤其是步行速度和步长(ICC分别为0.53和0.62)。使用Bland Altman 95%一致性界限对IDEEA和3-DGA测量值进行有效性比较,结果显示存在测量偏差,与3-DGA相比,IDEEA在两个受试者组中均高估了步幅和步长,低估了步频。对照受试者的95%一致性界限(步幅±0.20米;步长±0.27米;步行速度±0.28米/秒)比脑瘫受试者(步幅±0.36米;步长±0.37米;速度±0.58米/秒)更小。可能需要进行改进,以提高IDEEA在儿童中的可靠性和有效性,特别是在神经疾病中的应用。