Abstract

Functional lymphatic imaging was demonstrated in the abdomen and anterior hindlimb of anesthetized, intact Yorkshire swine by using near-infrared (NIR) fluorescence imaging following intradermal administration of 100-200 microl of 32 microM indocyanine green (ICG) and 64 microM hyaluronan NIR imaging conjugate to target the lymph vascular endothelial receptor (LYVE)-1 on the lymph endothelium. NIR fluorescence imaging employed illumination of 780 nm excitation light ( approximately 2 mW/cm(2)) and collection of 830 nm fluorescence generated from the imaging agents. Our results show the ability to image the immediate trafficking of ICG from the plexus, through the vessels and lymphangions, and to the superficial mammary, subiliac, and middle iliac lymph nodes, which were located as deep as 3 cm beneath the tissue surface. "Packets" of ICG-transited lymph vessels of 2-16 cm length propelled at frequencies of 0.5-3.3 pulses/min and velocities of 0.23-0.75 cm/s. Lymph propulsion was independent of respiration rate. In the case of the hyaluronan imaging agent, lymph propulsion was absent as the dye progressed immediately through the plexus and stained the lymph vessels and nodes. Lymph imaging required 5.0 and 11.9 microg of ICG and hyaluronan conjugate, respectively. Our results suggest that microgram quantities of NIR optical imaging agents and their conjugates have a potential to image lymph function in patients suffering from lymph-related disorders.

摘要

在麻醉状态下完整的约克夏猪的腹部和后肢前部进行了功能性淋巴成像。通过皮内注射100 - 200微升32微摩尔/升的吲哚菁绿(ICG)和64微摩尔/升的透明质酸近红外成像偶联物,以靶向淋巴管内皮上的淋巴管内皮受体(LYVE)-1,然后使用近红外(NIR)荧光成像。近红外荧光成像采用780纳米激发光(约2毫瓦/平方厘米)照明,并收集成像剂产生的830纳米荧光。我们的结果表明能够对ICG从丛状淋巴管,通过血管和淋巴管节,到位于组织表面下方深达3厘米的浅表乳腺、髂下和髂中淋巴结的即时运输进行成像。长度为2 - 16厘米的ICG通过的淋巴管“束”以0.5 - 3.3次脉冲/分钟的频率和0.23 - 0.75厘米/秒的速度推进。淋巴推进与呼吸频率无关。对于透明质酸成像剂,由于染料立即通过丛状淋巴管并对淋巴管和淋巴结进行染色,所以没有淋巴推进现象。淋巴成像分别需要5.0微克和11.9微克的ICG和透明质酸偶联物。我们的结果表明,微克量的近红外光学成像剂及其偶联物有可能对患有淋巴相关疾病的患者的淋巴功能进行成像。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验