对退伍军人事务部国家外科质量改进计划所收集数据的可靠性评估。

Assessment of the reliability of data collected for the Department of Veterans Affairs national surgical quality improvement program.

作者信息

Davis Chester L, Pierce John R, Henderson William, Spencer C David, Tyler Christine, Langberg Robert, Swafford Jennan, Felan Gladys S, Kearns Martha A, Booker Brigitte

机构信息

Department of Veterans Affairs, Washington, DC 20420, USA.

出版信息

J Am Coll Surg. 2007 Apr;204(4):550-60. doi: 10.1016/j.jamcollsurg.2007.01.012. Epub 2007 Mar 2.

Abstract

BACKGROUND

The Office of the Medical Inspector of the Department of Veterans Affairs (VA) studied the reliability of data collected by the VA's National Surgical Quality Improvement Program (NSQIP). The study focused on case selection bias, accuracy of reports on patients who died, and interrater reliability measurements of patient risk variables and outcomes.

STUDY DESIGN

Surgical data from a sample of 15 VA medical centers were analyzed. For case selection bias, reviewers applied NSQIP criteria to include or exclude 2,460 patients from the database, comparing their results with those of NSQIP staff. For accurate reporting of patients who died, reviewers compared Social Security numbers of 10,444 NSQIP records with those found in the VA Beneficiary Identification and Records Locator Subsystem, VA Patient Treatment Files, and Social Security Administration death files. For measurement of interrater reliability, reviewers reabstracted 59 variables in each of 550 patient medical records that also were recorded in the NSQIP database.

RESULTS

On case selection bias, the reviewers agreed with NSQIP decisions on 2,418 (98%) of the 2,460 cases. Computer record matching identified 4 more deaths than the NSQIP total of 198, a difference of about 2%. For 52 of the categorical variables, agreement, uncorrected for chance, was 96%. For 48 of 52 categorical variables, kappas ranged from 0.61 to 1.0 (substantial to almost perfect agreement); none of the variables had kappas of less than 0.20 (slight to poor agreement).

CONCLUSIONS

This sample of medical centers shows adherence to criteria in selecting cases for the NSQIP database, for reporting deaths, and for collecting patient risk variables.

摘要

背景

退伍军人事务部医疗检查办公室研究了退伍军人事务部国家外科质量改进计划(NSQIP)收集数据的可靠性。该研究聚焦于病例选择偏倚、死亡患者报告的准确性以及患者风险变量和结果的评分者间信度测量。

研究设计

分析了来自15个退伍军人事务部医疗中心样本的手术数据。对于病例选择偏倚,审查人员应用NSQIP标准从数据库中纳入或排除2460例患者,并将其结果与NSQIP工作人员的结果进行比较。对于死亡患者的准确报告,审查人员将10444条NSQIP记录的社会保障号码与退伍军人事务部受益人识别和记录定位子系统、退伍军人事务部患者治疗档案以及社会保障管理局死亡档案中的号码进行比较。对于评分者间信度的测量,审查人员重新提取了NSQIP数据库中也记录的550份患者病历中每份病历的59个变量。

结果

在病例选择偏倚方面,审查人员在2460例病例中的2418例(98%)上与NSQIP的决定一致。计算机记录匹配识别出的死亡病例比NSQIP总计的198例多4例,差异约为2%。对于52个分类变量,未经机遇校正的一致性为96%。对于52个分类变量中的48个,卡帕值范围为0.61至1.0(实质性至几乎完美一致);没有变量的卡帕值小于0.20(轻微至差的一致性)。

结论

该医疗中心样本显示在为NSQIP数据库选择病例、报告死亡以及收集患者风险变量方面符合标准。