Abstract

In eight edentulous subjects, who had not previously worn dentures, blood flow was measured by 133Xe clearance after intramucosal injection. Upper and lower complete dentures were then constructed for these subjects, and 133Xe clearance was measured after the dentures had been worn for 7 and 40 days. Before the insertion of dentures the mean blood flow to palatal mucosa was 18.9 +/- 7.1 ml/100 g/min. Seven and 40 days after wearing dentures the mean flows to the palatal mucosa were 10.6 +/- 4.5 and 12.6 +/- 5.3 ml/100 g/min, respectively. The difference before and after wearing dentures was statistically significant (p less than 0.05). The subjects were asked not to wear the dentures for 24 h after the third visit on the 40th day whereupon the blood flow reached almost normal levels (16.2 +/- 5.45 ml/100 g/min). The findings show that wearing dentures hinders the blood supply to the palatal mucosa, and that after resting the oral tissues, blood flow may return to normal levels.

摘要

在8名此前未佩戴过假牙的无牙受试者中,通过黏膜内注射后用133Xe清除法测量血流量。然后为这些受试者制作上下全口假牙,并在佩戴假牙7天和40天后测量133Xe清除率。在插入假牙前,腭黏膜的平均血流量为18.9±7.1 ml/100 g/min。佩戴假牙7天和40天后,腭黏膜的平均血流量分别为10.6±4.5和12.6±5.3 ml/100 g/min。佩戴假牙前后的差异具有统计学意义(p<0.05)。在第40天第三次就诊后,要求受试者24小时不佩戴假牙,此时血流量几乎恢复到正常水平(16.2±5.45 ml/100 g/min)。研究结果表明,佩戴假牙会阻碍腭黏膜的血液供应,并且在口腔组织休息后,血流量可能会恢复到正常水平。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验