Suppr超能文献

采血系统对使用人源和兔源凝血活酶试剂测定的凝血酶原时间及国际敏感指数的影响。

Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents.

作者信息

van den Besselaar Anton M H P, Hoekstra Martha M C L, Witteveen Evelina, Didden Jan H, van der Meer Felix J M

机构信息

Hemostasis and Thrombosis Research Center, Department of Hematology, Leiden University Medical Center, Leiden, The Netherlands.

出版信息

Am J Clin Pathol. 2007 May;127(5):724-9. doi: 10.1309/NW194EAMD4WMEHJD.

Abstract

Three brands of blood collection tubes were studied for their influence on the prothrombin time (PT) and international sensitivity index (ISI) for 5 commercial thromboplastin reagents. With all reagents, PTs were shorter in Vacutainer (Becton Dickinson Vacutainer Systems, Plymouth, England) samples than in S-Monovette (Sarstedt, Nümbrecht, Germany) or Venosafe (Terumo Europe, Leuven, Belgium) samples. ISI values were higher with Vacutainer samples than with S-Monovette or Venosafe samples. The ISI differences between the tubes were small for Thromborel-S (2.1%; Dade Behring, Marburg, Germany) and Hepato Quick (1.1%; Diagnostica Stago, Asnières, France; Roche Diagnostics Nederland, Almere, the Netherlands) but greater for Neoplastin Plus (5.5%; Diagnostica Stago; Roche Diagnostics Nederland), Simplastin HTF (8.3%; bioMérieux, Durham, NC), and Innovin (8.8%; Dade Behring). The PT and ISI differences between the tubes could be explained mostly by the effect of magnesium ion contamination in the sodium citrate solutions. When PT ratios were transformed into international normalized ratios (INRs) using crossover ISI (ie, samples collected with one type of tube and ISI determined with another collection system for the PT reagent), the differences in mean INRs could be approximately 10%. For ISI calibration of reference thromboplastins, blood collection tubes should be used with minimal divalent metal ion contamination of the citrate solution.

摘要

研究了三种品牌的采血管对5种商用凝血活酶试剂的凝血酶原时间(PT)和国际敏感指数(ISI)的影响。使用所有试剂时,Vacutainer(英国普利茅斯的贝克顿·迪金森真空采血管系统公司)样本的PT比S-Monovette(德国纽姆布雷希特的赛多利斯公司)或Venosafe(比利时鲁汶的泰尔茂欧洲公司)样本的PT短。Vacutainer样本的ISI值高于S-Monovette或Venosafe样本。Thromborel-S(德国马尔堡的达德·贝林公司)和Hepato Quick(法国阿斯尼埃的诊断斯塔戈公司;荷兰阿尔梅勒的罗氏诊断荷兰公司)的采血管之间的ISI差异较小,但Neoplastin Plus(诊断斯塔戈公司;罗氏诊断荷兰公司)、Simplastin HTF(美国北卡罗来纳州达勒姆的生物梅里埃公司)和Innovin(达德·贝林公司)的差异较大。采血管之间的PT和ISI差异主要可以用柠檬酸钠溶液中镁离子污染的影响来解释。当使用交叉ISI将PT比值转换为国际标准化比值(INR)时(即使用一种采血管采集样本,并使用另一种采血管系统测定PT试剂的ISI),平均INR的差异可能约为10%。对于参考凝血活酶的ISI校准,应使用柠檬酸盐溶液中二价金属离子污染最小的采血管。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验