Abstract

The traditional approach to the diagnosis of viral hepatitis has been to collect a serum sample and to test it for the presence of hepatitis B surface antigen (HBsAg), IgM to the core of HBV (anti-HBc IgM) and IgM to HAV (anti-HAV IgM) by solid phase radio- or enzyme immunoassays. Microparticle enzyme immunoassay technology (IMx-Abbott Laboratories) has been introduced as an automated carousel system for the detection of these markers. A side-by-side, blinded comparison of IMx to current IA was performed for HBsAg on 659 specimens submitted from March to July 1990, of which 72 (10.8%) were positive by AUSRIA (Abbott RIA for HBsAg) and 2 of these were discordant in IMx. Both were near the cutoff and by confirmatory testing one was positive and the other negative. Forty three percent (25/58) of frozen stored sera tested for anti-HBc IgM, by IMx, were positive by EIA (Corzyme M). One specimen near the cutoff was negative by EIA but weakly positive by IMx. Anti-HAV IgM was found in 21.8% (46/211) of sera with 100% correlation by IMx. Thus IMx had the following percent sensitivies and specificities: HBsAg; 98.6, 99.9; anti-HBc IgM; 100, 99.9; anti-HAV IgM; 100, 100. The test set-up times for the 3 markers in the IMx were similar to the RIA and EIA. The turnover time was 45 min for a full IMx carousel compared to: AUSRIA-short incubation (4 h), or long incubation (14 h); Corzyme M-short (4.75 h) or long (20 h); anti-HAV IgM (23 h).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

传统的病毒性肝炎诊断方法是采集血清样本,通过固相放射免疫测定法或酶免疫测定法检测乙型肝炎表面抗原(HBsAg)、抗乙肝核心抗体 IgM(抗 - HBc IgM)和抗甲型肝炎病毒抗体 IgM(抗 - HAV IgM)。微粒体酶免疫测定技术(IMx - 雅培实验室)已作为一种自动转盘系统被引入用于检测这些标志物。1990年3月至7月提交的659份标本进行了 HBsAg 的 IMx 与当前免疫测定法的双盲平行比较,其中72份(10.8%)经 AUSRIA(雅培 HBsAg 放射免疫测定法)检测为阳性,其中2份在 IMx 检测中结果不一致。两者均接近临界值,经确证检测,一份为阳性,另一份为阴性。通过 IMx 检测抗 - HBc IgM 的冷冻保存血清中,43%(25/58)经酶免疫测定法(Corzyme M)检测为阳性。一份接近临界值的标本经酶免疫测定法检测为阴性,但经 IMx 检测为弱阳性。在211份血清中,21.8%(46/211)检测到抗 - HAV IgM,IMx 检测的相关性为100%。因此,IMx 的灵敏度和特异性百分比分别为:HBsAg;98.6,99.9;抗 - HBc IgM;100,99.9;抗 - HAV IgM;100,100。IMx 中三种标志物的检测准备时间与放射免疫测定法和酶免疫测定法相似。完整的 IMx 转盘周转时间为45分钟,相比之下:AUSRIA - 短孵育(4小时)或长孵育(14小时);Corzyme M - 短(4.75小时)或长(20小时);抗 - HAV IgM(23小时)。(摘要截选至250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验