Suppr超能文献

利用灌注和整体式反相高效液相色谱法对转Bt基因玉米品种和非转基因玉米品种的蛋白质组分进行表征。通过多变量分析对玉米进行鉴别。

Characterization of protein fractions from Bt-transgenic and non-transgenic maize varieties using perfusion and monolithic RP-HPLC. Maize differentiation by multivariate analysis.

作者信息

Rodríguez-Nogales José M, Cifuentes Alejandro, García María C, Marina María L

机构信息

Area de Tecnología de los Alimentos, Departamento de Ing. Agraria y Forestal, ETS de Ingenierías Agrarias, Universidad de Valladolid, 34004 Palencia, Spain.

出版信息

J Agric Food Chem. 2007 May 16;55(10):3835-42. doi: 10.1021/jf063579e. Epub 2007 Apr 21.

Abstract

Protein fractions from transgenic Bt and non-transgenic maize varieties, extracted by the Osborne solvent fraction procedure, were characterized for the first time by perfusion and monolithic RP-HPLC in very short analysis times. Albumins and globulins from different transgenic Bt maizes as well as from their non-transgenic isogenic varieties were eluted in four peaks using perfusion RP-HPLC, whereas prolamins and glutelins were separated in seven peaks. Monolithic RP-HPLC enabled the separation of maize proteins in a large number of peaks showing 6 and 10 main peaks for albumins and globulins, respectively. Prolamins migrated at retention times higher than 5 min as seven peaks, whereas glutelins were separated in three main peaks appearing at retention times higher than 6.0 min. Moreover, chromatograms of the whole protein extracts showed 8 and 11 components for perfusion and monolithic RP-HPLC, respectively. A comparison of the chromatograms of the whole protein extracts relative to transgenic and non-transgenic varieties evidenced quantitative differences on the percentages of area, mainly for peaks 2 and 3 by perfusion RP-HPLC and for peaks 3 and 7 by monolithic RP-HPLC. A discriminant analysis based on these proteic profiles was carried out to classify and predict transgenic Bt maize lines, achieving 100% correct classification using perfusion RP-HPLC.

摘要

采用奥斯本溶剂分级法从转基因Bt玉米和非转基因玉米品种中提取蛋白质组分,首次在极短的分析时间内通过灌注和整体式反相高效液相色谱(RP-HPLC)对其进行了表征。使用灌注RP-HPLC时,不同转基因Bt玉米及其非转基因同基因品种中的白蛋白和球蛋白在四个峰中洗脱,而醇溶蛋白和谷蛋白则在七个峰中分离。整体式RP-HPLC能够将玉米蛋白分离成大量峰,白蛋白和球蛋白分别显示出6个和10个主峰。醇溶蛋白在保留时间高于5分钟时以七个峰的形式迁移,而谷蛋白在保留时间高于6.0分钟时分离成三个主峰。此外,全蛋白提取物的色谱图显示,灌注RP-HPLC和整体式RP-HPLC分别有8个和11个组分。对转基因和非转基因品种全蛋白提取物的色谱图进行比较,发现面积百分比存在定量差异,主要是灌注RP-HPLC中的峰2和峰3以及整体式RP-HPLC中的峰3和峰7。基于这些蛋白质谱进行判别分析,以对转基因Bt玉米品系进行分类和预测,使用灌注RP-HPLC时分类正确率达到100%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验