Suppr超能文献

采用火焰原子吸收光谱法测定茶叶样品中锌、铜和镍的微波辅助消解程序的优化。

Optimization of microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry.

作者信息

Soylak Mustafa, Tuzen Mustafa, Souza Anderson Santos, das Graças Andrade Korn Maria, Ferreira Sérgio Luis Costa

机构信息

Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039-Kayseri, Turkey.

出版信息

J Hazard Mater. 2007 Oct 22;149(2):264-8. doi: 10.1016/j.jhazmat.2007.03.072. Epub 2007 Mar 27.

Abstract

The present paper describes the development of a microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry (FAAS). The optimization step was performed using a full factorial design (2(3)) involving the factors: composition of the acid mixture (CMA), microwave power (MP) and radiation time (RT). The experiments of this factorial were carried out using a certified reference material of tea GBW 07605 furnished by National Research Centre for Certified Reference Materials, China, being the metal recoveries considered as response. The relative standard deviations of the method were found below 8% for the three elements. The procedure proposed was used for the determination of copper, zinc and nickel in several samples of tea from Turkey. For 10 tea samples analyzed, the concentration achieved for copper, zinc and nickel varied at 6.4-13.1, 7.0-16.5 and 3.1-5.7 (microg g(-1)), respectively.

摘要

本文描述了一种采用火焰原子吸收光谱法(FAAS)测定茶叶样品中锌、铜和镍的微波辅助消解方法的开发。优化步骤采用全因子设计(2(3)),涉及的因素有:酸混合物组成(CMA)、微波功率(MP)和辐射时间(RT)。该因子实验使用了中国国家计量科学研究院提供的茶叶标准物质GBW 07605,将金属回收率视为响应值。该方法对三种元素的相对标准偏差均低于8%。所提出的方法用于测定来自土耳其的多个茶叶样品中的铜、锌和镍。对10个茶叶样品进行分析后,铜、锌和镍的浓度分别在6.4 - 13.1、7.0 - 16.5和3.1 - 5.7(μg g(-1))范围内变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验