Suppr超能文献

腹主动脉覆膜支架移植物的体内顺行开窗术

In vivo antegrade fenestration of abdominal aortic stent-grafts.

作者信息

Tse Leonard W H, Bui Bao T, Lerouge Sophie, Salazkin Igor, Therasse Eric, Benko Andrew, Héon Hélène, Oliva Vincent L, Soulez Gilles

机构信息

Division of Vascular Surgery, Peter Lougheed Centre, University of Calgary, Alberta, Canada.

出版信息

J Endovasc Ther. 2007 Apr;14(2):158-67. doi: 10.1177/152660280701400207.

Abstract

PURPOSE

To examine in a canine model the feasibility of antegrade fenestration of abdominal aortic stent-grafts to preserve the patency of the renal arteries.

METHODS

Two large dogs underwent antegrade fenestration of stent-grafts in the perirenal aorta. Before fenestration, bare stents were inserted in both renal arteries as fluoroscopic landmarks. A 12-mm iliac extension served as the canine aortic endograft. The first procedure was done under ultrasound and fluoroscopic guidance, using an intravascular ultrasound (IVUS) probe inserted in the vena cava and a Pioneer IVUS catheter. The second was performed exclusively under fluoroscopic guidance with a Brockenbrough needle. Angiograms and duplex ultrasound were planned for 1 month, after which the dogs would be sacrificed for autopsy. The explanted endograft was subjected to biomaterials analysis, with a focus on fabric tear.

RESULTS

Perforation of the aortic graft and catheterization of the renal arteries with a floppy guidewire were possible in both animals. In dog 1, aortic graft dilation and subsequent fenestration were not possible, and the experiment was terminated. However, the procedure was successful in both renal arteries of dog 2. At 1-month follow-up in this dog, both renal arteries were patent. Stent fractures were observed bilaterally. There was no extension of the damage to the fabric beyond the area of fenestration.

CONCLUSION

In vivo antegrade fenestration of aortic endografts is technically feasible. However, improvements in technique, instrumentation, and materials are required to make it a reliable and reproducible way of allowing stent-graft vascularization of aortic side branches.

摘要

目的

在犬类模型中研究腹主动脉覆膜支架移植物顺行开窗以保留肾动脉通畅性的可行性。

方法

对两只大型犬的肾周主动脉进行覆膜支架移植物顺行开窗。开窗前,在双侧肾动脉中插入裸支架作为透视标记。一个12毫米的髂动脉延长段用作犬主动脉内移植物。第一次操作在超声和透视引导下进行,使用插入腔静脉的血管内超声(IVUS)探头和先锋IVUS导管。第二次操作仅在透视引导下使用布罗肯布罗针进行。计划在1个月后进行血管造影和双功超声检查,之后处死犬进行尸检。对取出的内移植物进行生物材料分析,重点是织物撕裂情况。

结果

两只动物均成功实现主动脉移植物穿孔并用软头导丝插入肾动脉。在犬1中,无法进行主动脉移植物扩张及随后的开窗,实验终止。然而,在犬2的双侧肾动脉中该操作均成功。在这只犬1个月的随访中,双侧肾动脉均通畅。双侧均观察到支架骨折。开窗区域以外的织物未出现损伤扩展。

结论

主动脉内移植物的体内顺行开窗在技术上是可行的。然而,需要在技术、器械和材料方面进行改进,使其成为一种可靠且可重复的方法,以实现主动脉侧支的支架移植物血管化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验