Kim B H, Kim J S, Kim J L, Kim Y S, Yang T G, Lee M Y
Korea Atomic Energy Research Institute, PO Box 105, Yuseong, Daejeon 305-600, Republic of Korea.
Radiat Prot Dosimetry. 2007;126(1-4):384-9. doi: 10.1093/rpd/ncm079. Epub 2007 May 15.
High energy proton induced neutron fluence spectra were determined at the Korea Institute of Radiological and Medical Sciences (KIRAMS) using an extended Bonner Sphere (BS) set from the Korea Atomic Energy Research Institute (KAERI) in a series of measurements to quantify the neutron field. At the facility of the MC50 cyclotron of KIRAMS, two Be targets of different thicknesses, 1.0 and 10.5 mm, were bombarded by 35 and 45-MeV protons to produce six kinds of neutron fields, which were classified according to the measurement position and the use or no use of a beam collimator such as the gantry of the neutron therapy unit. In order to obtain a priori information to unfold the measured BS data the MCNPX code was used to calculate the neutron spectrum, and the influence of the surrounding materials for cooling the target assembly were also reviewed through this calculation. Some dosimetric quantities were determined by using the spectra determined in this measurement. Dose equivalent rates of these neutron fields ranged from 0.21 to 5.66 mSv h(-1)nA(-1) and the neutron yields for a thick Be target were 3.05 and 4.77% in the case of using a 35 and a 45-MeV proton, respectively.
在韩国放射医学科学研究所(KIRAMS),使用韩国原子能研究所(KAERI)提供的一套扩展型邦纳球(BS)装置,通过一系列测量确定了高能质子诱发的中子注量能谱,以量化中子场。在KIRAMS的MC50回旋加速器设施中,用35 MeV和45 MeV的质子轰击两块不同厚度(1.0 mm和10.5 mm)的铍靶,产生六种中子场,这些中子场根据测量位置以及是否使用中子治疗单元的机架等束流准直器进行分类。为了获得用于解卷积测量的BS数据的先验信息,使用MCNPX代码计算中子能谱,并通过该计算评估了用于冷却靶组件的周围材料的影响。利用本次测量确定的能谱确定了一些剂量学量。这些中子场的剂量当量率范围为0.21至5.66 mSv h(-1)nA(-1),在使用35 MeV和45 MeV质子的情况下,厚铍靶的中子产额分别为3.05%和4.77%。