Van Campenhout Anja, Moens Pierre, Fabry Guy
Department of Orthopaedics, University Hospitals Leuven, Pellenberg, Belgium.
Acta Orthop Belg. 2007 Apr;73(2):196-9.
Serial bone scintigraphy in Legg-Calvé-Perthes disease (LCP) has a good early prognostic value. So far, no intra- and inter-observer reliability study on this classification has been published. Serial technetium scintigraphy of the hips was performed in 40 children with LCP disease, and the hips were classified based on their scintigraphic patterns according to Conway. Forty hips were classified twice by six observers. The two assessments were made in a different order, with a minimum time interval of one month. Unweighted kappa coefficients were calculated. Only moderate reliability was measured: intra-observer reliability: kappa = 0.573 and inter-observer reliability: kappa = 0.525. Serial bone scintigraphy in LCP has an inter- and intra-observer reliability that is only moderate. The reliability is better than that observed for the radiological Catterall classification and head-at-risk factors, but worse than the reliability of the radiological Herring classification.
在莱-卡-佩病(LCP)中,连续骨闪烁扫描具有良好的早期预后价值。到目前为止,尚未发表关于该分类的观察者内和观察者间可靠性研究。对40例LCP病患儿进行了髋关节系列锝闪烁扫描,并根据康威的方法根据闪烁扫描模式对髋关节进行分类。六名观察者对40个髋关节进行了两次分类。两次评估以不同顺序进行,最短时间间隔为一个月。计算了非加权kappa系数。仅测量到中等可靠性:观察者内可靠性:kappa = 0.573,观察者间可靠性:kappa = 0.525。LCP中的连续骨闪烁扫描在观察者间和观察者内的可靠性仅为中等。该可靠性优于放射学卡特拉尔分类和股骨头危险因子的可靠性,但低于放射学赫林分类的可靠性。