Suppr超能文献

某学术医疗中心心脏装置植入与取出的输血方案

Transfusion protocol for implantation and explantation of cardiac devices in an academic medical center.

作者信息

Bartley Angela N, Redford Daniel T, Berg Mary P

机构信息

Department of Pathology, University of Arizona Health Sciences Center, Tucson, Arizona, USA.

出版信息

ASAIO J. 2007 May-Jun;53(3):320-3. doi: 10.1097/MAT.0b013e318034095c.

Abstract

Few reports in the literature describe the transfusion support needed for implantation and explantation of cardiac assist devices. Because such devices are frequently used at this institution, we have established a protocol to support these patients. We reviewed blood bank records to document the usage of blood components in all patients on cardiac assist devices from 1989 to 2005 (n = 215). The data were separated into components given at the time of implantation and explantation of the device. Implantation data on 214 patients showed the mean use as follows: red blood cells (RBC), 5.7 U; platelets (PLT), 2.4 U; fresh frozen plasma (FFP), 7.5 U; and cryoprecipitate, 0 U. Explantation data on 134 patients showed a mean use as follows: RBC, 7.7 U; PLT, 2.4 U; FFP, 9.9 U; and cryoprecipitate, 3.7 U. Our protocol for the preparation of blood components for implantation and explantation of a cardiac device is, implantation: RBC, 4 U; PLT, 1 U; FFP, 6 U; explantation: RBC, 8 U; PLT, 2 U; FFP, 8 U. Our data do not support the need for preparation of cryoprecipitate before implantation or explantation.

摘要

文献中很少有报告描述心脏辅助装置植入和取出时所需的输血支持。由于该机构经常使用此类装置,我们制定了一项方案来支持这些患者。我们查阅了血库记录,以记录1989年至2005年期间所有使用心脏辅助装置患者的血液成分使用情况(n = 215)。数据分为装置植入和取出时给予的成分。214例患者的植入数据显示平均使用量如下:红细胞(RBC),5.7单位;血小板(PLT),2.4单位;新鲜冰冻血浆(FFP),7.5单位;冷沉淀,0单位。134例患者的取出数据显示平均使用量如下:RBC,7.7单位;PLT,2.4单位;FFP,9.9单位;冷沉淀,3.7单位。我们关于心脏装置植入和取出时血液成分准备的方案是,植入:RBC,4单位;PLT,1单位;FFP,6单位;取出:RBC,8单位;PLT,2单位;FFP,8单位。我们的数据不支持在植入或取出前准备冷沉淀的必要性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验