Burkhart Harold M, Joyner Nitasha, Niles Scott, Ploessl Jay, Everett Jeff, Iannettoni Mark, Richenbacher Wayne
Department of Cardiothoracic Surgery, University of Iowa Hospitals and Clinics, Children's Hospital of Iowa, Iowa City, Iowa, USA.
ASAIO J. 2007 May-Jun;53(3):365-7. doi: 10.1097/MAT.0b013e3180317395.
Many centers advocate the use of a standby wet-primed extracorporeal membrane oxygenation (ECMO) circuit for rapid deployment during cardiopulmonary resuscitation. However, concerns with regard to the potential health hazards associated with the release of the plasticizer di-2(ethylhexyl)phthalate (DEHP) from the polyvinyl chloride (PVC) tubing exist. The purpose of this study was to determine the time course of DEHP release from a preprimed ECMO circuit and to evaluate the effect of PVC tubing coatings on DEHP release. Seven circuits including three uncoated (Medtronic, Medtronic with albumin, and Medtronic Super Tygon) and four attenuated surfaces (Carmeda, COBE Smart, Medtronic Trillium, and Terumo x-coated) were primed with Plasmalyte A. Samples of the circuit prime were collected over a period of 2 weeks and were analyzed for DEHP, using gas chromatography. Results were compared by using a two-tailed t test. One coated (Carmeda) and all three uncoated circuits leached DEHP. The greatest amount of leaching occurred in the uncoated Medtronic tubing with albumin. The COBE Smart, Medtronic Trillium, and Terumo x-coated circuits had undetectable amounts of DEHP (p = 0.006 vs Medtronic uncoated). Prepriming an ECMO circuit composed of uncoated PVC tubing is associated with DEHP release. Using coated PVC tubing appears to eliminate DEHP release over a 2-week period.
许多中心主张在心肺复苏期间使用备用的湿预充体外膜肺氧合(ECMO)回路以便快速部署。然而,对于聚氯乙烯(PVC)管路中增塑剂邻苯二甲酸二(2-乙基己基)酯(DEHP)的释放所带来的潜在健康危害存在担忧。本研究的目的是确定DEHP从预充的ECMO回路中的释放时间过程,并评估PVC管路涂层对DEHP释放的影响。七个回路,包括三个未涂层的(美敦力、含白蛋白的美敦力和美敦力超级泰贡)和四个表面经过处理的(卡美达、COBE Smart、美敦力延龄草和泰尔茂x涂层),用Plasmalyte A进行预充。在两周的时间内收集回路预充液样本,并使用气相色谱法分析DEHP。结果通过双尾t检验进行比较。一个涂层的(卡美达)和所有三个未涂层的回路都有DEHP浸出。浸出量最大的是含白蛋白的未涂层美敦力管路。COBE Smart、美敦力延龄草和泰尔茂x涂层回路中未检测到DEHP(与未涂层的美敦力相比,p = 0.006)。预充由未涂层PVC管路组成的ECMO回路与DEHP释放有关。使用涂层PVC管路似乎在两周内消除了DEHP的释放。