To reduce adverse reactions due to platelet (PLT) transfusion, medical solutions on the market, such as saline and ACD-A, are used to replace the plasma of PLT concentrates in Japan; however, they are not strongly preservative. Here, an attempt was made to develop a novel additive solution (M-sol) having the ability to preserve PLTs stably, with only approved solutions for clinical use.
M-sol is a mixture of solutions for medical use, which consists of 77 mmol per L NaCl, 3 mmol per L KCl, 1 mmol per L CaCl2, 21 mmol per L Na acetate, 15 mmol per L glucose, 9.4 mmol per L Na3 citrate, 4.8 mmol per L citric acid, 44 mmol per L NaHCO3, and 1.6 mmol per L MgSO4. The in vitro variables of PLTs stored in M-sol, Seto-sol, PASIIIM, or 100 percent plasma were compared during 14 days of storage.
The in vitro parameters (pH, P-selectin, %hypotonic shock response, %disk, mean PLT volume, aggregability) of PLTs were better maintained in M-sol containing 3 percent plasma than in 100 percent plasma, PASIIIM with 31 percent plasma, and Seto-sol with 3 percent plasma during 14 days of storage.
The 2-week storage of PLTs in M-sol is feasible in terms of the in vitro PLT function. Our results here show that the additive solution, with a high ability to preserve PLTs, can be prepared by mixing solutions approved for clinical use that are not specifically for PLT storage.
为减少血小板(PLT)输注引起的不良反应,在日本,市场上的医用溶液(如生理盐水和ACD - A)被用于替代血小板浓缩液中的血浆;然而,它们的防腐能力不强。在此,尝试开发一种新型添加剂溶液(M - 溶液),该溶液仅使用临床使用的批准溶液,就能稳定保存血小板。
M - 溶液是一种医用溶液混合物,由每升77毫摩尔氯化钠、每升3毫摩尔氯化钾、每升1毫摩尔氯化钙、每升21毫摩尔醋酸钠、每升15毫摩尔葡萄糖、每升9.4毫摩尔柠檬酸钠、每升4.8毫摩尔柠檬酸、每升44毫摩尔碳酸氢钠和每升1.6毫摩尔硫酸镁组成。在储存14天期间,比较了储存在M - 溶液、Seto - 溶液、PASIIIM或100%血浆中的血小板的体外变量。
在储存14天期间,含有3%血浆的M - 溶液中血小板的体外参数(pH值、P - 选择素、低渗休克反应百分比、盘状百分比、平均血小板体积、聚集性)比100%血浆、含31%血浆的PASIIIM和含3%血浆的Seto - 溶液中维持得更好。
就体外血小板功能而言,血小板在M - 溶液中储存两周是可行的。我们在此的结果表明,通过混合临床使用批准的、并非专门用于血小板储存的溶液,可以制备出具有高血小板保存能力的添加剂溶液。