Suppr超能文献

Periodontal aspects of osseointegrated fixtures supporting an overdenture. A 4-year retrospective study.

作者信息

Quirynen M, Naert I, van Steenberghe D, Teerlinck J, Dekeyser C, Theuniers G

机构信息

Department of Periodontoly, School of Dentistry, Oral Pathology & Maxillo-Facial Surgery, Catholic University of Leuven, Belgium.

出版信息

J Clin Periodontol. 1991 Nov;18(10):719-28. doi: 10.1111/j.1600-051x.1991.tb00063.x.

Abstract

196 Brånemark implants in 86 consecutive patients rehabilitated by means of overdentures (6 upper jaws, 80 lower jaws) were observed longitudinally. In each jaw, only 2 implants were used to anchor the overdenture. 2 implants in the lower jaw showed some mobility at the abutment installation and were removed immediately. During the loading period (mean loading time 19.1 months ranging from 4 to 48 months), none of the implants showed any signs of non-integration. The marginal tissue reaction and plaque accumulation were monitored using conventional indices. Clinical methods and standardized radiographs were used to evaluate the bone level and density. The numbers of approximal surfaces without plaque (40%) or with gingival inflammation (55%) were almost constant throughout the study. The probing pocket depths remained within the range of 2.7 to 3.2 mm during the observation time, whereas the distance of the gingival margin from the top of the abutment clearly increased (from 1.8 to 2.9 mm). For loaded lower jaw implants connected to each other with a straight bar, a radiographic bone loss of 0.8 mm was observed during the first postsurgical year followed by a mean annual bone loss of less than 0.1 mm. For the "sleeping" fixtures, 50% less bone loss was recorded. For loaded but not interconnected implants in the upper jaw, the bone loss during the first 6 months reached 2.0 mm. The loss in marginal bone height did not clearly correlate with parameters such as the plaque index, the gingivitis index, the presence or absence of gingiva around the abutment, or the implant length. The present data, with an observation time up to 4 years, showed that the failure rate for Brånemark implants supporting overdentures in the lower jaw can be limited to 1%. However, the use of 2 unconnected fixtures in the upper jaw cannot presently be advocated since considerable bone loss was observed.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验