Suppr超能文献

混合表面活性剂胶束中组成分布的对比变化小角中子散射研究

Contrast variation SANS investigation of composition distributions in mixed surfactant micelles.

作者信息

Almgren Mats, Garamus Vasil M, Asakawa Tsuyoshi, Jiang Nan

机构信息

Department of Physical and Analytical Chemistry, Uppsala University, Uppsala, Sweden.

出版信息

J Phys Chem B. 2007 Jun 28;111(25):7133-41. doi: 10.1021/jp070271x. Epub 2007 May 26.

Abstract

Small angle neutron scattering measurements have been performed on three systems (HFDeP-d5-C (N-1(1,1,2,2-tetrahydroperfluorodecanoyl)pyridinium-d5 chloride)/C16PC in 63 mM NaCl; HFDeP-d5-C/C12PC in 200 mM NaCl, and as an example of an ideally mixed system, SDS/SDS-d25 in 200 mM NaCl) containing micelles formed in a binary mixture of surfactants, in order to investigate the composition distribution of the mixed micelles. The experimental data were collected varying the contrast between the average scattering length density of micelles and aqueous solvent by changing the H2O/D2O ratio. Analysis of data includes a model-independent approach--the indirect Fourier transformation method and direct modeling-simultaneous fit at all contrasts by the scattering from micelles of equal size and shape with composition distribution and an effective interaction. It has earlier been shown (Almgren, M.; Garamus, V. M. J. Phys. Chem. B 2005, 109, 11348) that for micelles of equal size, independent of the composition, and with negligible intermicellar interactions, the scattered intensity at zero angle varies quadratically with the contrast, with the minimum intensity at the nominal match point proportional to sigma2, the variance of the micelle composition distribution. Within the regular solution framework, the composition distribution and its variance are uniquely defined by the value of the interaction parameter and the micelle aggregation number. At 25 degrees C, the first system gave sigma = 0.37, corresponding to a broad, bimodal composition distribution, the second sigma = 0.22, a broad distribution with a shallow minimum at the midpoint. For SDS/SDS-d25, we found sigma = 0.006 +/- 0.030, which is a smaller value than that of the binominal composition distribution expected for an ideally mixed system.

摘要

已对三种体系(63 mM NaCl中的HFDeP-d5-C(N-1(1,1,2,2-四氢全氟癸酰基)吡啶鎓-d5氯)/C16PC;200 mM NaCl中的HFDeP-d5-C/C12PC,以及作为理想混合体系示例的200 mM NaCl中的SDS/SDS-d25)进行了小角中子散射测量,这些体系含有在表面活性剂二元混合物中形成的胶束,以研究混合胶束的组成分布。通过改变H2O/D2O比例来改变胶束与水相溶剂的平均散射长度密度之间的对比度,从而收集实验数据。数据分析包括一种与模型无关的方法——间接傅里叶变换法,以及直接建模——通过具有组成分布和有效相互作用的等尺寸和形状的胶束散射在所有对比度下进行同时拟合。较早前已表明(阿尔姆格伦,M.;加拉穆斯,V. M.《物理化学杂志B》2005年,109卷,11348页),对于等尺寸的胶束,与组成无关且胶束间相互作用可忽略不计,零角度处的散射强度随对比度呈二次方变化,在标称匹配点处的最小强度与胶束组成分布的方差σ2成正比。在正规溶液框架内,组成分布及其方差由相互作用参数值和胶束聚集数唯一确定。在25℃时,第一个体系的σ = 0.37,对应于宽泛的双峰组成分布,第二个体系的σ = 0.22,是在中点处有浅最小值的宽泛分布。对于SDS/SDS-d25,我们发现σ = 0.006 ± 0.030,这一值比理想混合体系预期的二项式组成分布的值要小。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验