Shrestha B M
Sheffield Kidney Institute, Northern General Hospital, Sheffield, UK.
J Vasc Access. 2007 Apr-Jun;8(2):120-2.
Early thrombosis of a polytetrafluoroethylene (PTFE) graft used for hemodialysis vascular access can result from technical error or hypotension and hypovolaemia in the immediate postoperative period. Massaging a graft to dislodge a freshly formed thrombus with a view to restoring blood flow can lead to acute limb ischaemia from embolisation of the artery as a result of migration of the thrombus from the arterial end of the graft, hence massaging of thrombosed grafts should be avoided. This report describes the management of a 35-year-old diabetic male who developed acute ischaemia of hand due to embolisation of the radial artery following massage of a thrombosed brachio-basilic forearm PTFE loop graft.
用于血液透析血管通路的聚四氟乙烯(PTFE)移植物早期血栓形成可能是由于技术失误或术后即刻出现的低血压和血容量不足所致。为恢复血流而按摩移植物以清除新形成的血栓,可能会因血栓从移植物动脉端迁移导致动脉栓塞,进而引起急性肢体缺血,因此应避免对血栓形成的移植物进行按摩。本报告描述了一名35岁糖尿病男性的治疗情况,该患者因对血栓形成的肱-桡侧前臂PTFE袢状移植物进行按摩后,桡动脉发生栓塞,导致手部急性缺血。