Zhao Hui, Chen Mingli, Van Veen Barry D, Strasburger Janette F, Wakai Ronald T
Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53706, USA.
IEEE Trans Biomed Eng. 2007 Jun;54(6 Pt 2):1167-71. doi: 10.1109/TBME.2006.889198.
The difficulty of utilizing multimodality diagnostic imaging techniques for fetal surveillance remains one of the greatest challenges in providing enhanced prenatal care. In this Letter we demonstrate the feasibility of performing fetal magnetocardiography (fMCG) and ultrasound/Doppler imaging simultaneously, using a multichannel SQUID magnetometer and a portable ultrasound scanner. Despite large magnetic interference from the scanner, the implementation of simple noise reduction procedures and appropriate signal processing techniques yielded fMCG recordings of sufficient quality for assessment of fetal heart rate and rhythm. A variation of reference channel filtering, referred to here as synthetic reference channel filtering, was used to reduce nonstationary low-frequency interference. The combination of fMCG and/or fMEG with ultrasound/Doppler offers new possibilities for assessment of fetal well-being and fetal cardiac function.
利用多模态诊断成像技术进行胎儿监测的困难仍然是提供强化产前护理面临的最大挑战之一。在本信函中,我们展示了使用多通道超导量子干涉仪磁力计和便携式超声扫描仪同时进行胎儿磁心动图(fMCG)和超声/多普勒成像的可行性。尽管扫描仪产生了很大的磁干扰,但实施简单的降噪程序和适当的信号处理技术后,获得了质量足以评估胎儿心率和心律的fMCG记录。一种参考通道滤波的变体,在此称为合成参考通道滤波,用于减少非平稳低频干扰。fMCG和/或胎儿脑磁图(fMEG)与超声/多普勒的结合为评估胎儿健康状况和胎儿心脏功能提供了新的可能性。