Hayashi Ken, Hayashi Hideyuki
Hayashi Eye Hospital, Fukuoka, Japan.
Am J Ophthalmol. 2007 Aug;144(2):195-202. doi: 10.1016/j.ajo.2007.04.044. Epub 2007 Jun 5.
To examine the influence of optic material on posterior capsule opacification (PCO) by comparing PCO and visual functions between eyes with an acrylic intraocular lens (IOLs) and those with a silicone IOL of the same optic design and with the same haptics.
Randomized clinical trial.
One hundred patients scheduled for phacoemulsification surgery underwent implantation of an acrylic IOL (AMO Sensar; AR40e) in one eye and implantation of a silicone IOL (ClariFlex) of the same optic design and loops in the fellow eye. Eighty-nine patients (89%) remained for analysis. The PCO value was measured using the Scheimpflug videophotography system at one, three, six, 12, 18, 24, 30, and 36 months postoperatively. The incidence of eyes that required a neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy was examined; visual acuity and contrast sensitivity with and without a glare source were also evaluated.
The mean PCO value did not increase significantly during follow-up in either the acrylic or silicone IOL group. When comparing the groups, no statistically significant difference was found in the PCO or in the incidence of Nd:YAG capsulotomy, although both tended to be slightly better in the silicone group than in the acrylic group. There was also no significant difference between the groups in visual acuity or in photopic and mesopic contrast sensitivity with or without glare.
When acrylic and silicone IOLs are of the same optic design and with the same haptics, the optic material does not influence the development of PCO enough to impair visual function.
通过比较植入相同光学设计和襻的丙烯酸酯人工晶状体(IOL)眼与硅酮IOL眼的后囊膜混浊(PCO)及视觉功能,研究光学材料对PCO的影响。
随机临床试验。
100例计划行超声乳化手术的患者,一只眼植入丙烯酸酯IOL(AMO Sensar;AR40e),另一只眼植入相同光学设计和襻的硅酮IOL(ClariFlex)。89例患者(89%)纳入分析。术后1、3、6、12、18、24、30和36个月,使用Scheimpflug摄像系统测量PCO值。检查需要钕:钇铝石榴石(Nd:YAG)激光后囊切开术的眼的发生率;还评估有无眩光光源时的视力和对比敏感度。
随访期间,丙烯酸酯IOL组和硅酮IOL组的平均PCO值均未显著增加。比较两组时,PCO或Nd:YAG后囊切开术的发生率无统计学显著差异,尽管硅酮组的这两项指标均略优于丙烯酸酯组。两组在视力以及有无眩光时的明视觉和暗视觉对比敏感度方面也无显著差异。
当丙烯酸酯IOL和硅酮IOL具有相同的光学设计和襻时,光学材料对PCO发展的影响不足以损害视觉功能。