Suppr超能文献

维他经典比色板中L*a*b*值的变化

Variations of L*a*b* values among Vitapan Classical Shade Guides.

作者信息

King Kenneth A, deRijk Waldemar G

机构信息

Department of Restorative Dentistry, University of Tennessee, College of Dentistry, Memphis, TN 38163, USA.

出版信息

J Prosthodont. 2007 Sep-Oct;16(5):352-6. doi: 10.1111/j.1532-849X.2007.00207.x. Epub 2007 Jun 9.

Abstract

PURPOSE

To measure the variations in Lab* values of a group of 25 guides and to assess whether shade guides are indeed interchangeable.

MATERIALS AND METHODS

The Lab* values of individual shade tabs were measured with a LabScan(tm) XE scanning spectrocolorimeter (SSC) with a special attachment for reproducibly positioning shade tabs. Each shade guide (Vitapan Classical, Vident) contained 16 shade tabs. Absolute calibration of the SSC was performed with color tiles traceable to NIST. One shade guide was used to determine the reproducibility of the experimental method by measuring and then removing each shade tab of the standard 10 times. This assessed the variations in observed values induced by the measurement method and the geometry of the specimens. The entire sample consisted of 25 shade guides. The tabs of each of the 25 shade guides were read five times in the SSC, without moving the specimen. Measurements and calculations of E, L*, a*, and b* were performed using Universal Software V4.10 (Hunter Associates Laboratory). The mean, standard deviation, and range were determined of the E, L*, a*, and b* values for each one of the 16 shades in the shade guides. Differences in color are expressed as DeltaE in color science. The standard deviation of E (E(sd)) and the range of E (E(r)) for each of the shades were used as a DeltaE value to assess color differences.

RESULTS

For the reproducibility measurements, the shades had values for E(r) varying from 0.08 to 0.69, and E(sd) between 0.02 and 0.22. This established the detection limit for our method for each of the shades. For the group of 25 shade guides, E(r) varied from 0.75 to 3.05, and E(sd) from 0.22 to 0.54. The difference in value of E(r) obtained from the reproducibility test and the E(r) of the group of 25 guides is significant at p < 0.05. The same was found for E(sd). The largest reproducible E(r) observed was 3.05 for shade C1.

CONCLUSIONS

The differences observed between shade guides are larger than the variations induced by the experimental method. The difference in E values for the shades C1 and C2 is 2.19; hence the observed E(r) of 3.05 between shade tabs of the same shade (C1) is larger than the changes in color between shades. This large a variation in what are claimed as identical shade tabs is deemed of clinical importance, and therefore, the shade guides should not be considered interchangeable.

摘要

目的

测量一组25个比色板的Lab*值变化,并评估比色板是否真的可以互换。

材料与方法

使用配备特殊附件的LabScan(tm) XE扫描分光色度计(SSC)测量各个比色片的Lab值,该附件用于可重复定位比色片。每个比色板(维他经典比色板、Vident比色板)包含16个比色片。使用可追溯到美国国家标准与技术研究院(NIST)的色卡对SSC进行绝对校准。使用一个比色板,通过对标准比色片各测量10次然后移除,来确定实验方法的可重复性。这评估了测量方法和样本几何形状引起的观测值变化。整个样本由25个比色板组成。在不移动样本的情况下,对25个比色板中的每个比色片在SSC中读取5次。使用通用软件V4.10(亨特联合实验室)进行E、L、a和b的测量与计算。确定比色板中16种颜色各自的E、L*、a和b值的平均值、标准差和范围。颜色差异在颜色科学中用ΔE表示。每种颜色的E的标准差(E(sd))和E的范围(E(r))用作ΔE值来评估颜色差异。

结果

对于可重复性测量,各颜色的E(r)值在0.08至0.69之间变化,E(sd)在0.02至0.22之间。这确定了我们方法对每种颜色的检测限。对于25个比色板组,E(r)在0.75至3.05之间变化,E(sd)在0.22至0.54之间。可重复性测试得到的E(r)值与25个比色板组的E(r)值差异在p < 0.05时具有显著性。E(sd)也是如此。观察到的最大可重复性E(r)是比色片C1的3.05。

结论

比色板之间观察到的差异大于实验方法引起的变化。比色片C1和C2的E值差异为2.19;因此,同一颜色(C1)的比色片之间观察到的E(r)为3.05,大于不同颜色之间的颜色变化。在所谓相同的比色片中有如此大的变化被认为具有临床重要性,因此,比色板不应被视为可互换的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验