Suppr超能文献

骨水泥型股骨假体节段性柄部骨折

Segmental stem fracture of a cemented femoral prosthesis.

作者信息

Jarvi Kristiina, Kerry Robert M

机构信息

Department of Orthopaedics, Sheffield Teaching Hospitals NHS Trust, Northern General Hospital, Sheffield, United Kingdom.

出版信息

J Arthroplasty. 2007 Jun;22(4):612-6. doi: 10.1016/j.arth.2006.03.012. Epub 2007 Jan 22.

Abstract

We report an unusual case of segmental stem fracture in 4 places of a cemented femoral prosthesis in a 43-year-old man 4 years after total hip arthroplasty. To our knowledge, this is the first reported case of segmental stem fracture. Detailed analysis of the prosthesis was performed at an independent testing laboratory. Initiation of all the cracks occurred on the medial aspect on the stem where the manufacturer's identification lettering was present, and the fractures occurred sequentially along the stem from distal to proximal. Laser etching is likely to have caused the microstructural alterations found on the surface of the stem, which, in turn, predisposed to fatigue cracking. Proximal debonding of the cement-bone interface observed in prefracture radiographs suggests that cantilever-bending stresses represented the initial mode of failure.

摘要

我们报告了一例不同寻常的病例,一名43岁男性在全髋关节置换术后4年,其骨水泥固定型股骨假体出现了4处节段性柄部骨折。据我们所知,这是首例报道的节段性柄部骨折病例。在一家独立检测实验室对假体进行了详细分析。所有裂纹均起始于柄部内侧有制造商标识字样的部位,骨折沿柄部从远端向近端依次发生。激光蚀刻很可能导致了柄部表面发现的微观结构改变,进而易引发疲劳裂纹。骨折前X线片观察到的骨水泥 - 骨界面近端脱粘表明,悬臂弯曲应力是初始失效模式。