Suppr超能文献

经导管微创重复异种移植植入的瓣中瓣概念

Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation.

作者信息

Walther Thomas, Falk Volkmar, Dewey Todd, Kempfert Jörg, Emrich Fabian, Pfannmüller Bettina, Bröske Petra, Borger Michael A, Schuler Gerhard, Mack Michael, Mohr Friedrich W

机构信息

Klinik für Herzchirurgie, Leipzig, Germany.

出版信息

J Am Coll Cardiol. 2007 Jul 3;50(1):56-60. doi: 10.1016/j.jacc.2007.03.030. Epub 2007 Jun 18.

Abstract

OBJECTIVES

This study sought to evaluate the feasibility of minimally invasive transapical repeat valve-in-a-valve (VinV) implantation.

BACKGROUND

Reoperative heart valve replacement for degenerated xenografts is associated with an increased surgical risk.

METHODS

Conventional Carpentier Edwards porcine aortic (n = 5) and mitral (n = 2) valve prostheses were implanted in 7 pigs. Transapical VinV implantation of a pericardial xenograft fixed within a 23-mm stainless steel, balloon expandable stent (Cribier Edwards, Edwards Lifesciences, Irvine, California) was then performed under fluoroscopic and echocardiographic visualization on the beating heart with ventricular unloading via cardiopulmonary bypass and rapid ventricular pacing.

RESULTS

Valve deployment was successfully performed in all cases. The radiopaque marking within the stent of the conventional aortic or mitral xenograft allowed for optimal positioning of the stent-delivered valve. All valves were firmly positioned without any migration. There were neither paravalvular nor transvalvular leaks, and good hemodynamic function was observed in all cases. All coronary arteries remained patent. Positioning and function were confirmed by autopsy in all animals.

CONCLUSIONS

The VinV concept is promising for minimally invasive beating heart repeat aortic or mitral valve replacement, using a stent-fixed sutureless prosthesis.

摘要

目的

本研究旨在评估经心尖微创重复瓣中瓣(VinV)植入术的可行性。

背景

因异种移植物退变而行再次心脏瓣膜置换术会增加手术风险。

方法

将传统的Carpentier Edwards猪主动脉瓣(n = 5)和二尖瓣(n = 2)假体植入7头猪体内。然后在透视和超声心动图引导下,在跳动的心脏上经心尖进行VinV植入术,使用固定在23毫米不锈钢球囊可扩张支架(Cribier Edwards,爱德华生命科学公司,加利福尼亚州欧文市)内的心包异种移植物,通过体外循环和快速心室起搏实现心室卸载。

结果

所有病例均成功完成瓣膜植入。传统主动脉或二尖瓣异种移植物支架内的不透射线标记有助于优化经支架输送瓣膜的定位。所有瓣膜均牢固定位,无任何移位。无瓣周漏或瓣内漏,所有病例均观察到良好的血流动力学功能。所有冠状动脉均保持通畅。所有动物均经尸检证实瓣膜定位及功能良好。

结论

VinV概念对于使用支架固定的无缝合假体进行微创跳动心脏再次主动脉或二尖瓣置换术具有前景。