To assess the effect extended exposure to disinfectant solutions has on the tensile load at failure and glass transition temperature (T(g)) of orthodontic elastomeric ligatures.
Elastomeric ligatures from three manufacturers: Rocky Mountain Orthodontics (RMO, Denver, Colo), American Orthodontics (AO, Sheboygan, Wis), and 3M Unitek (3M, Monrovia, Calif) were exposed to two disinfectant solutions, Vital Defense-D and Cidexplus, for up to 28 days. Unexposed ligatures were also tested. Tensile load at failure was determined by stretching the ligatures using a universal testing machine until they fractured. Glass transition temperature was determined using differential scanning calorimetry (DSC).
For tensile load at failure and glass transition temperature of the ligatures, significant differences were observed among the different manufacturers and exposure times. Type of disinfectant solution was a significant factor with T(g), but not with failure load. The 3M ligatures had the highest tensile load at failure and most positive T(g) followed by AO and RMO, respectively. Compared to unexposed ligatures, strength significantly decreased after one hour of disinfectant exposure. Glass transition temperature was also significantly affected with extended disinfectant exposure, but the different disinfectants changed T(g) in opposite directions.
Exposure of elastomeric ligatures to disinfectant solution for one hour or more decreases their strength.
评估长时间接触消毒溶液对正畸弹性结扎丝的断裂拉伸负荷及玻璃化转变温度(T(g))的影响。
来自三家制造商的弹性结扎丝:落基山正畸公司(RMO,科罗拉多州丹佛市)、美国正畸公司(AO,威斯康星州希博伊根市)和3M Unitek公司(3M,加利福尼亚州蒙罗维亚市),分别暴露于两种消毒溶液Vital Defense-D和Cidexplus中长达28天。同时对未暴露的结扎丝进行测试。通过使用万能试验机拉伸结扎丝直至其断裂来测定断裂拉伸负荷。使用差示扫描量热法(DSC)测定玻璃化转变温度。
对于结扎丝的断裂拉伸负荷和玻璃化转变温度,不同制造商和暴露时间之间存在显著差异。消毒溶液类型是影响T(g)的一个显著因素,但对断裂负荷无影响。3M结扎丝的断裂拉伸负荷最高,T(g)最正向,其次分别是AO和RMO。与未暴露的结扎丝相比,暴露于消毒溶液一小时后强度显著降低。延长消毒暴露时间也会显著影响玻璃化转变温度,但不同的消毒溶液使T(g)朝相反方向变化。
弹性结扎丝暴露于消毒溶液一小时或更长时间会降低其强度。