Budd J S, Langdon I, Brennan J, Bell P R
Department of Surgery, University of Leicester, UK.
Br J Surg. 1991 Nov;78(11):1379-80. doi: 10.1002/bjs.1800781135.
Prosthetic graft materials are used preferentially by a number of surgeons for above-knee femoropopliteal bypasses. Using B-mode ultrasonography we have assessed the ipsilateral long saphenous vein in patients undergoing such bypasses to determine its suitability for future use in more distal bypasses. A total of 137 above-knee prosthetic grafts were performed over a 10-year period. Of the patients, 74 were available for further assessment. Overall, 97 per cent of veins were suitable for future bypass surgery if required. Above-knee prosthetic bypasses do not appear to jeopardize the ipsilateral long saphenous vein.