OBJECTIVE

To assess and compare the prevalence, type and frequency of complications during Herbst treatment with reduced (canine to 2nd premolars) and total (canine to molars) mandibular cast splints.

SUBJECTS AND METHODS

Fifty consecutive Herbst patients treated with reduced mandibular splints (RMS) were compared to 182 consecutively treated Herbst patients with total mandibular splints (TMS). The prevalence, type and frequency of complications were analyzed.

RESULTS

The prevalence of patients with complications did not differ significantly between the groups, and amounted to 58% in the RMS- and 60% in the TMS-group. The most frequent type of complication in both groups was maxillary splint loosening, making up 56.3% of all complications in the RMS- and 66.9% in the TMS-group. The second most frequent complication was mandibular splint loosening, which amounted to 32.5% of the complications in the RMS- and 26.8% in the TMS-group. We observed telescope breakage twice as often (8.8%) in the RMS- as in the TMS-group (4.3%).

CONCLUSIONS

Loosening of the maxillary splints is the main complication during Herbst treatment with RMS and TMS. A reduction in mandibular splint length does not increase the prevalence of complications, but it does reduce expenses, and can thus be recommended for further use.

摘要

目的

评估并比较使用缩短型(从尖牙至第二前磨牙)和全长型(从尖牙至磨牙)下颌铸造夹板进行Herbst矫治时并发症的发生率、类型及发生频率。

对象与方法

将连续50例使用缩短型下颌夹板(RMS)治疗的Herbst患者与连续182例使用全长型下颌夹板(TMS)治疗的Herbst患者进行比较。分析并发症的发生率、类型及发生频率。

结果

两组患者并发症的发生率无显著差异,RMS组为58%,TMS组为60%。两组最常见的并发症类型均为上颌夹板松动,在RMS组中占所有并发症的56.3%,在TMS组中占66.9%。第二常见的并发症是下颌夹板松动,在RMS组并发症中占32.5%,在TMS组中占26.8%。我们观察到RMS组望远镜折断的发生率(8.)是TMS组(4.3%)的两倍。

结论

使用RMS和TMS进行Herbst矫治时,上颌夹板松动是主要并发症。缩短下颌夹板长度不会增加并发症的发生率,但可降低费用,因此可推荐进一步使用。