Suppr超能文献

用于评估肝脏和心肌铁含量的改进横向弛豫率测量技术。

Improved transverse relaxation rate measurement techniques for the assessment of hepatic and myocardial iron content.

作者信息

Song Ruitian, Cohen Alan R, Song Hee Kwon

机构信息

Laboratory for Structural NMR Imaging, Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania, USA.

出版信息

J Magn Reson Imaging. 2007 Jul;26(1):208-14. doi: 10.1002/jmri.20994.

Abstract

PURPOSE

To develop and validate an optimized respiratory-gated, gradient-echo sampling of free induction decay and echo (GESFIDE) pulse sequence for the simultaneous measurement of R2, R2*, and R2' in the liver or heart.

MATERIALS AND METHODS

Fifteen subjects (12 thalassemia patients and three normal volunteers) were scanned using an optimized navigator-gated GESFIDE pulse sequence for the measurement of R2, R2*, and R2' in the liver and heart. For imaging the myocardium, dark-blood preparation was used to suppress the blood signal to improve accuracy. The results were compared with those obtained from breath-held GESFIDE and multi-gradient-echo (GRE) scans.

RESULTS

Good agreement between breath-held and navigator-gated scans was found for R2, R2*, and R2' values in the liver (slopes = 0.97-0.99, r = 0.997-0.998, P < 0.0001) and for R2* in the heart (slope = 1.02, r = 0.85, P < 0.0001). Both R2* and R2' were closely correlated to R2 in the liver, with correlation factors of 0.998 and 0.994, respectively, but weaker correlations were observed in the heart (r = 0.72 for R2* vs. R2 and r = 0.51 for R2' vs. R2).

CONCLUSION

The improved sequence enables free-breathing measurements of transverse relaxation rates of the myocardium and liver. The method precludes the need for multiple breath-held scans and possible misregistration issues, and may prove most beneficial for imaging young children and patients who may have difficulty with prolonged or repeated breath-holds.

摘要

目的

开发并验证一种优化的呼吸门控、自由感应衰减与回波梯度回波采样(GESFIDE)脉冲序列,用于同时测量肝脏或心脏中的R2、R2*和R2'。

材料与方法

使用优化的导航门控GESFIDE脉冲序列对15名受试者(12名地中海贫血患者和3名正常志愿者)进行扫描,以测量肝脏和心脏中的R2、R2*和R2'。为了对心肌成像,采用黑血准备技术抑制血液信号以提高准确性。将结果与屏气GESFIDE和多梯度回波(GRE)扫描获得的结果进行比较。

结果

在肝脏中,屏气扫描和导航门控扫描的R2、R2和R2'值之间具有良好的一致性(斜率=0.97 - 0.99,r = 0.997 - 0.998,P < 0.0001),在心脏中R2的一致性也较好(斜率=1.02,r = 0.85,P < 0.0001)。肝脏中R2和R2'均与R2密切相关,相关系数分别为0.998和0.994,但在心脏中相关性较弱(R2与R2的r = 0.72,R2'与R2的r = 0.51)。

结论

改进后的序列能够在自由呼吸状态下测量心肌和肝脏的横向弛豫率。该方法无需多次屏气扫描以及可能出现的配准错误问题,对于幼儿和难以长时间或重复屏气的患者成像可能最为有益。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验