基于有限元法的放射治疗可变形图像配准评估

FEM-based evaluation of deformable image registration for radiation therapy.

作者信息

Zhong Hualiang, Peters Terry, Siebers Jeffrey V

机构信息

Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298, USA.

出版信息

Phys Med Biol. 2007 Aug 21;52(16):4721-38. doi: 10.1088/0031-9155/52/16/001. Epub 2007 Jul 24.

Abstract

This paper presents a new concept to automatically detect the neighborhood in an image where deformable registration is mis-performing. Specifically, the displacement vector field (DVF) from a deformable image registration is substituted into a finite-element-based elastic framework to calculate unbalanced energy in each element. The value of the derived energy indicates the quality of the DVF in its neighborhood. The new voxel-based evaluation approach is compared with three other validation criteria: landmark measurement, a finite element approach and visual comparison, for deformable registrations performed with the optical-flow-based 'demons' algorithm as well as thin-plate spline interpolation. This analysis was performed on three pairs of prostate CT images. The results of the analysis show that the four criteria give mutually comparable quantitative assessments on the six registration instances. As an objective concept, the unbalanced energy presents no requirement on boundary constraints in its calculation, different from traditional mechanical modeling. This method is automatic, and at voxel level suitable to evaluate deformable registration in a clinical setting.

摘要

本文提出了一种新概念,用于自动检测图像中可变形配准执行不佳的邻域。具体而言,将可变形图像配准得到的位移向量场(DVF)代入基于有限元的弹性框架中,以计算每个单元中的不平衡能量。导出能量的值表明其邻域中DVF的质量。将这种基于体素的新评估方法与其他三个验证标准进行了比较:地标测量、有限元方法和视觉比较,用于基于光流的“魔鬼”算法以及薄板样条插值进行的可变形配准。该分析在三对前列腺CT图像上进行。分析结果表明,这四个标准对六个配准实例给出了相互可比的定量评估。作为一个客观概念,不平衡能量在计算中对边界约束没有要求,这与传统的力学建模不同。该方法是自动的,并且在体素水平上适合于在临床环境中评估可变形配准。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验