Casademont Christophe, Pourcelly Gérald, Bazinet Laurent
Institute of Nutraceuticals and Functional Foods, Dairy Research Center (STELA), Department of Food Sciences and Nutrition, Pavillon Comtois, Université Laval, Sainte-Foy, QC G1K 7P4, Canada.
J Colloid Interface Sci. 2007 Nov 15;315(2):544-54. doi: 10.1016/j.jcis.2007.06.056. Epub 2007 Aug 10.
Electrodialysis is based on the migration of charged species through perm-selective membranes under an electric field. Fouling, which is the accumulation of undesired solid materials at the interfaces of these membranes, is one of the major problems of this process. The aim of the present work was to investigate the nature and the morphology of fouling observed at different Mg/Ca ratios (R=0, 1/20, 1/10, 1/5, 2/5) on cation-exchange membranes (CEM) during conventional electrodialysis treatments. It appeared that for R=0, the fouling observed on the surface in contact with the basified concentrate was formed of only Ca(OH)2. As soon as magnesium was introduced into the solution treated, CaCO3 was observed. Furthermore, the X-ray diffraction results also identified the CaCO3 observed as calcite. To our knowledge, this is the first time that the presence of magnesium has been demonstrated to induce a CaCO3 fouling on CEM during electrodialysis.
电渗析基于带电物质在电场作用下通过选择性渗透膜的迁移。污垢是指在这些膜的界面处积累不需要的固体物质,这是该过程的主要问题之一。本工作的目的是研究在常规电渗析处理过程中,在不同镁钙比(R = 0、1/20、1/10、1/5、2/5)下,阳离子交换膜(CEM)上观察到的污垢的性质和形态。结果表明,当R = 0时,在与碱化浓缩液接触的表面上观察到的污垢仅由Ca(OH)₂组成。一旦将镁引入处理过的溶液中,就会观察到CaCO₃。此外,X射线衍射结果还确定观察到的CaCO₃为方解石。据我们所知,这是首次证明在电渗析过程中镁的存在会在阳离子交换膜上诱导CaCO₃污垢。