Suppr超能文献

基于聚合物的临时冠和固定局部义齿材料边缘强度的体外研究

In vitro study of edge-strength of provisional polymer-based crown and fixed partial denture materials.

作者信息

Kim Sung-Hun, Watts David C

机构信息

Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, 275-1 Yeongeon-dong, Jongno-gu, Seoul 110-768, Republic of Korea.

出版信息

Dent Mater. 2007 Dec;23(12):1570-3. doi: 10.1016/j.dental.2007.06.023. Epub 2007 Aug 13.

Abstract

OBJECTIVES

To evaluate in vitro the edge-strength of polymer-based provisional crown and fixed partial denture materials at increasing distances from an edge.

METHODS

Three dimethacrylate-based provisional crown and fixed partial denture materials (Protemp 3 Garant, Luxatemp, and fast set Temphase) and one monomethacrylate-based one (Trim) were selected. Seven disk-shaped specimens of 12mm in diameter and 2.5mm in thickness for each material were fabricated and stored at 37 degrees C and 80% relative humidity for 1 month. The edge-strength was measured by using a CK 10 testing machine at a distance of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0mm from the edge of the specimen. All experiments were carried out in triplicate at each distance at 23+/-1 degrees C. The data were statistically analyzed using one-way ANOVA and the multiple comparison Scheffé test at the significance level of 0.05.

RESULTS

Trim showed severe deformation without chipping during loading at all distances. Protemp 3 Garant showed indentation at over 0.8mm from the edge, and for Luxatemp and fast set Temphase over 0.6mm from the edge without chipping. At 0.5mm from the edge, the highest values (2073.7N) were displayed by Protemp 3 Garant, approximately three times those of fast set Temphase (767.3N) and Luxatemp (697.0N) (p<0.05). The strengths of fast set Temphase and Luxatemp were not significantly different (p>0.05). Linear regression between the distance from the edge to 0.7mm and strength values of Protemp 3 Garant produced a correlation coefficient, R=0.99.

SIGNIFICANCE

The dimethacrylate-based provisional materials tested were stronger in edge-strength than the monomethacrylate-based one which showed severe deformation without fracture.

摘要

目的

在体外评估基于聚合物的临时冠和固定局部义齿材料在距边缘不同距离处的边缘强度。

方法

选择三种基于二甲基丙烯酸酯的临时冠和固定局部义齿材料(Protemp 3 Garant、Luxatemp和快速固化Temphase)以及一种基于单甲基丙烯酸酯的材料(Trim)。为每种材料制作7个直径12mm、厚度2.5mm的圆盘形试件,并在37℃和80%相对湿度下储存1个月。使用CK 10试验机在距试件边缘0.4、0.5、0.6、0.7、0.8、0.9和1.0mm处测量边缘强度。所有实验在23±1℃的每个距离处重复进行三次。数据采用单因素方差分析和多重比较Scheffé检验进行统计学分析,显著性水平为0.05。

结果

Trim在所有距离加载过程中均出现严重变形但无崩裂。Protemp 3 Garant在距边缘超过0.8mm处出现压痕,Luxatemp和快速固化Temphase在距边缘超过0.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验