Tosetto A, Rodeghiero F
Department of Haematology, San Bortolo Hospital, Vicenza, Italy.
Clin Lab Haematol. 1991;13(4):371-7. doi: 10.1111/j.1365-2257.1991.tb00301.x.
The authors review the statistical principles of parallel line bioassay and describe a computer program written to facilitate a correct approach to most coagulation assays. This program should be especially useful for those assays in which linearization of dose-response curves may prove difficult, or in which careful analysis of assay validity is required. How the knowledge of bioassay theory can be applied to von Willebrand factor Ristocetin Cofactor activity measurement is shown as a general example.
作者回顾了平行线生物测定的统计学原理,并描述了一个编写的计算机程序,以促进对大多数凝血测定采用正确的方法。该程序对于那些剂量-反应曲线可能难以线性化或需要仔细分析测定有效性的测定尤其有用。作为一个一般示例,展示了生物测定理论知识如何应用于血管性血友病因子瑞斯托霉素辅因子活性测量。