Suppr超能文献

辅助使用C形臂CT可消除肾上腺静脉采血的技术失败。

Adjunctive use of C-arm CT may eliminate technical failure in adrenal vein sampling.

作者信息

Georgiades Christos S, Hong Kelvin, Geschwind Jean-Francois, Liddell Robert, Syed Labib, Kharlip Julia, Arepally Aravind

机构信息

Division of Vascular and Interventional Radiology, Johns Hopkins Hospital, 600 North Wolfe Street, Blalock 545, Baltimore, Maryland 21287, USA.

出版信息

J Vasc Interv Radiol. 2007 Sep;18(9):1102-5. doi: 10.1016/j.jvir.2007.06.018.

Abstract

PURPOSE

To examine whether the use of C-arm computed tomography (CT) during adrenal vein sampling improves the technical success rate of the procedure.

MATERIALS AND METHODS

Nine consecutive patients with suspected primary hyperaldosteronism underwent standard adrenal vein sampling that included cortisol stimulation. The procedure was augmented with multiplanar C-arm CT images reconstructed from data acquired during a 180 degrees C-arm rotation. Whenever C-arm CT images showed the sampling catheter to be in the wrong position, the catheter was repositioned. Cortisol response was correlated to C-arm CT findings.

RESULTS

All patients had successful and diagnostic adrenal vein sampling. C-arm CT showed sampling catheter malposition in two patients (22%). Repeat C-arm CT after repositioning showed proper catheter location. Cortisol stimulation results and C-arm CT findings were concordant in 100% of cases.

CONCLUSIONS

C-arm CT is reliable in confirming the location of sampling catheters during adrenal vein sampling. If the 100% concordance between cortisol stimulation and C-arm CT findings is found in larger groups, the technical success rate may approach 100%. Cortisol stimulation may become obsolete and repeat procedures unnecessary, with significant time and cost savings.

摘要

目的

探讨在肾上腺静脉采血过程中使用C型臂计算机断层扫描(CT)是否能提高该操作的技术成功率。

材料与方法

连续9例疑似原发性醛固酮增多症患者接受了包括皮质醇刺激的标准肾上腺静脉采血。该操作通过从180度C型臂旋转过程中采集的数据重建的多平面C型臂CT图像得到辅助。每当C型臂CT图像显示采样导管位置错误时,就重新定位导管。将皮质醇反应与C型臂CT结果相关联。

结果

所有患者的肾上腺静脉采血均成功且具有诊断价值。C型臂CT显示2例患者(22%)采样导管位置不当。重新定位后重复C型臂CT显示导管位置正确。在100%的病例中,皮质醇刺激结果与C型臂CT结果一致。

结论

C型臂CT在肾上腺静脉采血过程中确认采样导管位置方面是可靠的。如果在更大的群体中发现皮质醇刺激与C型臂CT结果之间100%一致,技术成功率可能接近100%。皮质醇刺激可能会过时,重复操作也不再必要,从而显著节省时间和成本。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验