Suppr超能文献

在筛查和诊断测试条件下,婴儿宽带反射率测量的重测信度。

Test-retest reliability of wideband reflectance measures in infants under screening and diagnostic test conditions.

作者信息

Vander Werff Kathy R, Prieve Beth A, Georgantas Lea M

机构信息

Department of Communication Sciences and Disorders, Syracuse University, Syracuse, New York 13244, USA.

出版信息

Ear Hear. 2007 Sep;28(5):669-81. doi: 10.1097/AUD.0b013e31812f71b1.

Abstract

OBJECTIVE

The main goal of this study was to examine the test-retest reliability of wideband reflectance (WBR) measures collected from infants in screening and diagnostic hearing test environments. In addition, the results of WBR testing for infants who passed and failed otoacoustic emission (OAE) screening were examined to determine whether these measures distinguished between the two groups.

DESIGN

Repeated WBR measures were collected from two groups of infants, one group tested in an outpatient hearing screening setting and the other group in a diagnostic test setting. For a total of 127 infants and a control group of 10 adults, repeated WBR measurements were made with the probe left in place between the two tests (T1 and T2) and after reinsertion of the probe (T3) for a total of 3 measurements. Test-retest differences were calculated for each individual across one-third octave frequency bands, and the mean and 90th percentile were calculated by subject group and OAE results. WBR patterns were also compared between infants who passed versus failed OAE screening.

RESULTS

Mean test-retest differences were smaller for the diagnostic group than for the screening group. Test-retest differences were largest for the reinsertion condition and for the frequencies below 500 Hz. While the low frequencies were variable, the test-retest differences were smallest in the mid-frequency range which is thought to be the frequency range most sensitive to middle ear dysfunction. Test-retest performance did not differ between infants who passed or failed OAE screening. However, infants who failed OAE screening had significantly higher WBR in the range from 630 to 2000 Hz than infants who passed OAE screening.

CONCLUSIONS

Test-retest performance was poor for frequencies below 500 Hz, but in general test-retest differences were small across the important mid-frequency range. Reinsertion of the probe between repeated tests yielded larger and more variable test-retest differences. Careful monitoring of probe fit and testing while infants are in a quiet state appears to be critical for obtaining reliable WBR results. Analysis of WBR results indicated significantly higher reflected energy in the mid-frequency range for infants who failed OAE screening than for those who passed OAE screening. Although conclusions are limited by the fact that the true status of the middle ear and cochlea were not known for the infants in this study, this result may indicate that a number of these infants failed OAE screening due to transient or permanent middle ear dysfunction which was detected by WBR.

摘要

目的

本研究的主要目标是检验在筛查和诊断性听力测试环境中从婴儿收集的宽带反射率(WBR)测量值的重测信度。此外,还对通过和未通过耳声发射(OAE)筛查的婴儿的WBR测试结果进行了检查,以确定这些测量值能否区分这两组婴儿。

设计

从两组婴儿中收集重复的WBR测量值,一组在门诊听力筛查环境中进行测试,另一组在诊断测试环境中进行测试。对于总共127名婴儿和10名成人的对照组,在两次测试(T1和T2)之间以及重新插入探头后(T3)总共进行3次测量时,探头保持原位进行重复的WBR测量。计算每个个体在1/3倍频程频段的重测差异,并按受试者组和OAE结果计算平均值和第90百分位数。还比较了通过和未通过OAE筛查的婴儿之间的WBR模式。

结果

诊断组的平均重测差异小于筛查组。重测差异在重新插入探头的情况下以及低于500 Hz的频率时最大。虽然低频变化较大,但在被认为对中耳功能障碍最敏感的中频范围内,重测差异最小。通过或未通过OAE筛查的婴儿之间的重测表现没有差异。然而,未通过OAE筛查的婴儿在630至2000 Hz范围内的WBR明显高于通过OAE筛查的婴儿。

结论

低于500 Hz频率的重测表现较差,但总体而言,在重要的中频范围内重测差异较小。在重复测试之间重新插入探头会产生更大且更具变化性的重测差异。在婴儿处于安静状态时仔细监测探头的贴合情况和测试情况,对于获得可靠的WBR结果似乎至关重要。对WBR结果的分析表明,未通过OAE筛查的婴儿在中频范围内的反射能量明显高于通过OAE筛查的婴儿。尽管由于本研究中婴儿的中耳和耳蜗的真实状况未知,结论受到限制,但这一结果可能表明,这些婴儿中有许多未通过OAE筛查是由于WBR检测到的短暂或永久性中耳功能障碍。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验