Olszewski R, Zech F, Cosnard G, Nicolas V, Macq B, Reychler H
Department of Oral and Maxillofacial Surgery, Saint Luc University Clinics, Université Catholique de Louvain, 10, Av. Hippocrate, 1200 Brussels, Belgium.
Int J Oral Maxillofac Surg. 2007 Sep;36(9):828-33. doi: 10.1016/j.ijom.2007.05.022. Epub 2007 Sep 6.
The development of three-dimensional (3D) cephalometric analysis is essential for the computer-assisted planning of orthognathic surgery. The aim of this study was to transform and adapt Delaire's two-dimensional cephalometric analysis into the third dimension; this transposition was then validated. The comparative advantage of using 3D computed tomography (CT) surface renderings over profile X-rays was analysed. Comparison was made of inter- and intra-observer reproducibility of the cephalometric measurements done on profile X-rays and on 3D CT surface renderings on the same 26 dry skulls. The accuracy was also tested of the measurements done on 3D CT surface renderings (ACRO 3D) in relation to those directly taken on dry skulls with the help of a 3D measuring instrument. Inter- and intra-observer reproducibility proved significantly superior (p<0.0001) following the 3D CT method. There were no significant differences in the accuracy of measurements between the ACRO 3D software and the 3D measuring instrument. The ACRO 3D software was confirmed as being a reliable tool for developing 3D CT cephalometric analyses. Further research may entail clinical validation of the 3D CT craniofacial cephalometric method of analysis.
三维(3D)头影测量分析的发展对于正颌外科手术的计算机辅助规划至关重要。本研究的目的是将德莱尔的二维头影测量分析转换并应用到三维;然后对这种转换进行验证。分析了使用3D计算机断层扫描(CT)表面重建图像相对于侧面X线片的比较优势。对在26个相同的干燥颅骨上进行的侧面X线片和3D CT表面重建图像的头影测量在观察者间和观察者内的可重复性进行了比较。还测试了在3D CT表面重建图像(ACRO 3D)上进行的测量相对于借助3D测量仪器直接在干燥颅骨上进行的测量的准确性。观察者间和观察者内的可重复性在采用3D CT方法后被证明显著更高(p<0.0001)。ACRO 3D软件和3D测量仪器在测量准确性方面没有显著差异。ACRO 3D软件被确认为是开发3D CT头影测量分析的可靠工具。进一步的研究可能需要对3D CT颅面头影测量分析方法进行临床验证。