Baker Lisa, Balls Jennifer, Regnard Claud, Pridie Angus
Palliative Medicine, Marie Curie Hospice, Newcastle Upon Tyne, UK.
Palliat Med. 2007 Sep;21(6):543-5. doi: 10.1177/0269216307081130.
We describe six cases of head and neck or upper limb cancer palliative care patients with refractory pain, treated with an intrathecal catheter placed at cervical or upper thoracic spinal levels with a non-implanted, externalized and tunnelled delivery system. In these cases, this system was safe and effective.