Lim Hyun Kyoon, Chung Namsik, Kim Kiwoong, Ko Young-Guk, Kwon Hyukchan, Lee Yong-Ho, Kim Jin-Mok, Joung Boyoung, Kim Jin-Bae, Yu Kwon Kyu, Cho Jung-Rae, Kim In-Seon, Park Yong Ki
Korea Research Institute of Standards and Science, Daejeon, Korea.
Ann Med. 2007;39(8):617-27. doi: 10.1080/07853890701538040.
Magnetocardiography (MCG) has been proposed as a noninvasive diagnostic tool to risk-stratify patients with myocardial infarction (MI) and ischemia. The purpose of this study is to find the MCG parameters that are sensitive enough to detect the non-ST-segment elevation myocardial infarction (NSTEMI) patients.
MCG data were recorded and analyzed from 165 young controls (mean age = 27.2 +/- 9.0 years), 57 age-matched controls (mean age = 55.9 +/- 10.5 years) and 83 NSTEMI patients (mean age = 59.7 +/- 11.1 years). The MCG recordings were obtained using a 64-channel MCG system in a magnetically shielded room. Statistical analyses were performed for 24 parameters derived from QRS-, R-, T-wave, and ST-T period. Binary boundaries to detect NSTEMI patients out of control subjects were found using the receiver operating characteristic (ROC) curve for each parameter.
Fifteen parameters showed a significant difference (P < 0.05 and P < 0.01) between NSTEMI and both of the control groups. For detection of NSTEMI, the angle of the maximum current and the filed map angle on T-wave peak showed the highest diagnostic performance from 75% to 92% including accuracy, sensitivity, specificity, positive predictive value, and negative predictive value (area under ROC curve = 0.87 approximately 0.93).
Our study showed that MCG has potential clinical application for detection of NSTEMI and should be further investigated.
磁心动图(MCG)已被提议作为一种对心肌梗死(MI)和心肌缺血患者进行风险分层的非侵入性诊断工具。本研究的目的是寻找对检测非ST段抬高型心肌梗死(NSTEMI)患者足够敏感的MCG参数。
记录并分析了165名年轻对照组(平均年龄 = 27.2 ± 9.0岁)、57名年龄匹配的对照组(平均年龄 = 55.9 ± 10.5岁)和83名NSTEMI患者(平均年龄 = 59.7 ± 11.1岁)的MCG数据。使用64通道MCG系统在磁屏蔽室内获取MCG记录。对从QRS波、R波、T波和ST - T间期得出的24个参数进行了统计分析。利用每个参数的受试者工作特征(ROC)曲线找出将NSTEMI患者与对照受试者区分开来的二元界限。
15个参数在NSTEMI组与两个对照组之间均显示出显著差异(P < 0.05和P < 0.01)。对于NSTEMI的检测,最大电流角度和T波峰值处的场图角度显示出最高的诊断性能,包括准确性、敏感性、特异性、阳性预测值和阴性预测值,范围从75%到92%(ROC曲线下面积 = 0.87至0.93)。
我们的研究表明,MCG在检测NSTEMI方面具有潜在的临床应用价值,应进一步开展研究。