Recknagel Sebastian, Breitenbach Martin, Pautz Joachim, Lück Detlef
Federal Institute for Materials Research and Testing (BAM), Division of Inorganic-Chemical Analysis, Reference Materials, Richard-Willstaetter-Str. 11, D-12489 Berlin, Germany.
Anal Chim Acta. 2007 Sep 19;599(2):256-63. doi: 10.1016/j.aca.2007.07.062. Epub 2007 Aug 2.
The mass fraction of potassium hydrogen phthalate (KHP) from a specific batch was certified as an acidimetric standard. Two different analytical methods on a metrological level were used to carry out certification analysis: precision constant current coulometric and volumetric titration with NaOH. It could be shown that with a commercial automatic titration system in combination with a reliable software for the end-point detection it is possible to produce equivalent results with the same accuracy in comparison to a definite method handled by a fundamental apparatus for traceable precision coulometry. Prerequisite for titrations are that a high number of single measurement are applied which are calibrated with a high precision certified reference material.
某特定批次邻苯二甲酸氢钾(KHP)的质量分数被认证为酸碱滴定标准物质。采用两种不同的计量级分析方法进行认证分析:精密恒电流库仑法和用氢氧化钠进行的容量滴定法。结果表明,使用商业自动滴定系统并结合可靠的终点检测软件,与使用用于可溯源精密库仑法的基础仪器操作的确定方法相比,能够产生具有相同准确度的等效结果。滴定的前提条件是应用大量单次测量,并使用高精度认证参考物质进行校准。