Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities.

作者信息

Lindborg L, Bolognese-Milsztajn T, Boschung M, Coeck M, Curzio G, d'Errico F, Fiechtner A, Hallfarth D, Lievens B, Lillhök J-E, Lövefors-Daun A, Lacoste V, Luszik-Bhadra M, Reginatto M, Schuhmacher H, Tanner R, Vanhavere F

机构信息

Karolinska Institutet, Department of Medical Radiation Physics, SE 171 76 Stockholm, Sweden.

出版信息

Radiat Prot Dosimetry. 2007;124(3):213-8. doi: 10.1093/rpd/ncm394. Epub 2007 Sep 23.

Abstract

Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H(p)(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.

摘要

相似文献

1
Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities.
Radiat Prot Dosimetry. 2007;124(3):213-8. doi: 10.1093/rpd/ncm394. Epub 2007 Sep 23.
2
Performance of a PADC personal neutron dosemeter at simulated and real workplace fields of the nuclear industry.
Radiat Prot Dosimetry. 2007;126(1-4):314-7. doi: 10.1093/rpd/ncm065. Epub 2007 Jun 19.
4
Evaluation of individual monitoring in mixed neutron/photon fields: mid-term results from the EVIDOS project.
Radiat Prot Dosimetry. 2006;120(1-4):263-7. doi: 10.1093/rpd/ncj011. Epub 2006 Jun 17.
5
Individual neutron monitoring in workplaces with mixed neutron/photon radiation.
Radiat Prot Dosimetry. 2004;110(1-4):753-8. doi: 10.1093/rpd/nch220.
6
Summary of personal neutron dosemeter results obtained within the EVIDOS project.
Radiat Prot Dosimetry. 2007;125(1-4):293-9. doi: 10.1093/rpd/ncm190. Epub 2007 Apr 22.
8
Workplace monitoring of mixed neutron-photon radiation fields and its contribution to external dosimetry.
Radiat Prot Dosimetry. 2011 Mar;144(1-4):599-604. doi: 10.1093/rpd/ncq588. Epub 2011 Feb 1.
9
Performance of a personal neutron dosemeter based on direct ion storage at workplace fields in the nuclear industry.
Radiat Prot Dosimetry. 2007;125(1-4):323-6. doi: 10.1093/rpd/ncl383. Epub 2006 Nov 15.
10
Measuring cosmic-ray exposure in aircraft using real-time personal dosemeters.
Radiat Prot Dosimetry. 2012 Apr;149(2):169-76. doi: 10.1093/rpd/ncr221. Epub 2011 May 31.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验