Suppr超能文献

三维旋转数字减影血管造影术可能低估颅内动脉瘤:两个基底动脉瘤的研究结果

3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.

作者信息

Jou L-D, Mohamed A, Lee D H, Mawad M E

机构信息

Department of Radiology, Baylor College of Medicine, Houston, TX 77030, USA.

出版信息

AJNR Am J Neuroradiol. 2007 Oct;28(9):1690-2. doi: 10.3174/ajnr.A0652. Epub 2007 Sep 24.

Abstract

3D digital subtraction angiography (DSA) allows clinicians to review intracranial aneurysms and other vascular lesions. We report 2 basilar aneurysms that were imaged by both 3D DSA and DynaCT. These 2 techniques produced very different aneurysm appearances. Anterior portions of the aneurysms were invisible on 3D DSA but were revealed by DynaCT. These aneurysms appeared to have been flattened by image artifacts in 3D DSA. Pulsation and gravity are 2 possible causes of aneurysm underestimation.

摘要

3D数字减影血管造影(DSA)使临床医生能够查看颅内动脉瘤和其他血管病变。我们报告了2例经3D DSA和DynaCT成像的基底动脉瘤。这两种技术产生的动脉瘤外观差异很大。动脉瘤的前部在3D DSA上不可见,但在DynaCT上显示出来。这些动脉瘤在3D DSA中似乎因图像伪影而变平。搏动和重力是动脉瘤低估的两个可能原因。

相似文献

1
3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.
AJNR Am J Neuroradiol. 2007 Oct;28(9):1690-2. doi: 10.3174/ajnr.A0652. Epub 2007 Sep 24.
6
Benefits of 3D rotational DSA compared with 2D DSA in the evaluation of intracranial aneurysm.
Acad Radiol. 2012 Jun;19(6):701-7. doi: 10.1016/j.acra.2012.02.012.
9
Intravenous 3D digital subtraction angiography in the diagnosis of unruptured intracranial aneurysms.
AJNR Am J Neuroradiol. 2008 Jan;29(1):107-9. doi: 10.3174/ajnr.A0822. Epub 2007 Oct 9.

引用本文的文献

1
Comparative Study of Automated Algorithms for Brain Arteriovenous Malformation Nidus Extent Identification Using 3DRA.
Cardiovasc Eng Technol. 2023 Dec;14(6):801-809. doi: 10.1007/s13239-023-00688-w. Epub 2023 Oct 2.
4
Discrepancy between Angiography and Operative Findings of Small Side Wall Aneurysms in Atherosclerotic Parent Arteries.
J Cerebrovasc Endovasc Neurosurg. 2017 Mar;19(1):44-47. doi: 10.7461/jcen.2017.19.1.44. Epub 2017 Mar 31.
7
A workflow for patient-individualized virtual angiogram generation based on CFD simulation.
Comput Math Methods Med. 2012;2012:306765. doi: 10.1155/2012/306765. Epub 2012 Nov 4.
8
Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis.
AJNR Am J Neuroradiol. 2013 Jan;34(1):129-34. doi: 10.3174/ajnr.A3301. Epub 2012 Aug 30.
9
DSA volumetric 3D reconstructions of intracranial aneurysms: A pictorial essay.
Pol J Radiol. 2012 Apr;77(2):47-53. doi: 10.12659/pjr.882970.

本文引用的文献

1
The utility of DynaCT in neuroendovascular procedures.
AJNR Am J Neuroradiol. 2006 Feb;27(2):330-2.
2
Contrast settling in cerebral aneurysm angiography.
Phys Med Biol. 2005 Jul 7;50(13):3171-81. doi: 10.1088/0031-9155/50/13/014. Epub 2005 Jun 22.
4
Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries.
Physiol Meas. 2005 Aug;26(4):477-88. doi: 10.1088/0967-3334/26/4/013. Epub 2005 Apr 29.
5
Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils.
Radiology. 2004 Jun;231(3):653-8. doi: 10.1148/radiol.2313030460. Epub 2004 Apr 29.
8
Second-generation three-dimensional reconstruction for rotational three-dimensional angiography.
Acad Radiol. 1998 Dec;5(12):836-49. doi: 10.1016/s1076-6332(98)80244-4.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验