Suppr超能文献

脑部十六排螺旋CT血管造影:三种不同造影剂用量的比较

Sixteen-detector row CT angiography of the brain: comparison of 3 different volumes of the contrast material.

作者信息

Yoon Dae Young, Lim Kyoung Ja, Choi Chul Soon, Chang Suk Ki, Yun Eun Joo, Seo Young Lan, Lee Yu-Jin, Moon Jeung Hee, Park Se Hyuck, Song Hong Ki

机构信息

Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, Seoul, Korea.

出版信息

J Comput Assist Tomogr. 2007 Sep-Oct;31(5):671-6. doi: 10.1097/RCT.0b013e318031f53e.

Abstract

OBJECTIVE

The aim of this prospective study was to investigate the effect of different volumes of contrast material on vascular enhancement in 16-channel multi-detector row computed tomographic angiography of the brain.

METHODS

A total of 194 patients were divided into 3 groups who received different volumes of contrast material: 100 (n = 62), 80 (n = 72), and 60 mL (n = 60). The attenuation values were measured on transverse images at 12 different intracranial vessels (right and left internal carotid arteries, A2s, M2s, and P2s, basilar artery, vein of Galen, superior sagittal sinus, and dominant sigmoid sinus). The image quality parameters (intra-arterial contrast, arterial delineation, venous contamination, and confidence in diagnosis) were graded by 2 observers in consensus using a 5-point scale.

RESULTS

The attenuation values at the left A2 segment, superior sagittal sinus, and sigmoid sinus were significantly lower in the 60-mL group than those in other groups, whereas no significant differences were found between the 3 groups for the remaining intracranial vessels. For qualitative evaluation, arterial delineation was rated higher in the 100- and 80-mL groups, whereas less venous contamination was found in the 60-mL group. There was no significant difference in overall image quality (the sum of the scores for 4 image quality parameters) between the 3 groups.

CONCLUSIONS

A contrast material volume of 60 mL (18 g iodine) provides excellent image quality of cerebral multi-detector row computed tomographic angiography comparable to those achievable with 100 and 80 mL.

摘要

目的

本前瞻性研究旨在探讨不同体积的对比剂对脑部16排多层螺旋CT血管造影中血管强化的影响。

方法

总共194例患者被分为3组,分别接受不同体积的对比剂:100 mL(n = 62)、80 mL(n = 72)和60 mL(n = 60)。在12条不同的颅内血管(左右颈内动脉、A2段、M2段、P2段、基底动脉、大脑大静脉、上矢状窦和优势乙状窦)的横断面上测量衰减值。由2名观察者使用5分制对图像质量参数(动脉内对比、动脉显影、静脉污染和诊断信心)进行一致评分。

结果

60 mL组左侧A2段、上矢状窦和乙状窦的衰减值显著低于其他组,而其余颅内血管在3组之间未发现显著差异。对于定性评估,100 mL和80 mL组的动脉显影评分较高,而60 mL组的静脉污染较少。3组之间的整体图像质量(4个图像质量参数的得分总和)无显著差异。

结论

60 mL(18 g碘)的对比剂体积可提供与100 mL和80 mL相当的脑部多层螺旋CT血管造影的优良图像质量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验