Cancer yield of probably benign breast MR examinations.

作者信息

Eby Peter R, Demartini Wendy B, Peacock Sue, Rosen Eric L, Lauro Bridget, Lehman Constance D

机构信息

Department of Radiology, University of Washington Medical Center, Seattle, Washington, USA.

出版信息

J Magn Reson Imaging. 2007 Oct;26(4):950-5. doi: 10.1002/jmri.21123.

Abstract

PURPOSE

To evaluate the cancer yield, frequency of use, and follow-up compliance of breast MR examinations assessed as "probably benign."

MATERIALS AND METHODS

We retrospectively reviewed our MR database of 809 consecutive examinations between January 2003 and June 2004. We identified all examinations that ultimately received an MR breast imaging reporting and data system (BI-RADS) 3 assessment and recommendation for a short-interval follow-up MR with or without an antecedent targeted ultrasound. The clinical indication for breast MR, date of the follow-up examination, follow-up assessment, and any pathology findings through June 2005 were collected from clinical records and radiology and pathology reports. Frequency of BI-RADS 3 use, follow-up compliance, and cancer yield were calculated.

RESULTS

A total of 160 out of 809 (20%) examinations comprise the study population. A total of 100 out of 160 (63%) women returned for the recommended follow-up MR, in which three out of 100 (3%) were upgraded to BI-RADS 4 with biopsy recommended. One patient underwent biopsy and the result was benign. A total of seven out of 160 (4%) underwent mastectomy in lieu of MR for known cancer elsewhere in the breast. One out of seven mastectomy specimens contained malignancy that corresponded to the probably benign finding, resulting in a cancer yield of one out of 160 (0.6%).

CONCLUSION

Our data suggest that follow-up MR is a valid alternative to biopsy for MR BI-RADS 3 lesions.

摘要

目的

评估被判定为“可能为良性”的乳腺磁共振成像(MR)检查的癌症检出率、使用频率及随访依从性。

材料与方法

我们回顾性分析了2003年1月至2004年6月期间连续809例检查的MR数据库。我们确定了所有最终获得乳腺MR成像报告和数据系统(BI-RADS)3类评估并建议进行短期随访MR检查(无论是否先行靶向超声检查)的病例。从临床记录、放射学和病理学报告中收集乳腺MR检查的临床指征、随访检查日期、随访评估以及截至2005年6月的任何病理结果。计算BI-RADS 3类的使用频率、随访依从性和癌症检出率。

结果

809例检查中有160例(20%)纳入研究人群。160例女性中有100例(63%)接受了建议的随访MR检查,其中100例中有3例(3%)升级为BI-RADS 4类并建议活检。1例患者接受了活检,结果为良性。160例中有7例(4%)因乳腺其他部位已知癌症而接受了乳房切除术而非MR检查。7例乳房切除标本中有1例含有与可能为良性的发现相符的恶性肿瘤,癌症检出率为160例中的1例(0.6%)。

结论

我们的数据表明,对于MR BI-RADS 3类病变,随访MR是活检的有效替代方法。