Suppr超能文献

[毛细管气相色谱法定量测定油脂中的反式脂肪酸:日本油化学协会协同研究结果]

[Quantitative determination of trans-fatty acids in oils and fats by capillary gas chromatography: results of a JOCS collaborative study].

作者信息

Shirasawa Seiichi, Shiota Makoto, Arakawa Hiroshi, Shigematsu Yasuhiko, Yokomizo Kazuhisa, Shionoya Noriko, Okamoto Takahisa, Miyazaki Yousuke, Takahashi Shigeyuki, Himata Katsuichi

机构信息

The Nisshin OilliO Group, Ltd., Yokosuka, Kanagawa, Japan.

出版信息

J Oleo Sci. 2007;56(8):405-15. doi: 10.5650/jos.56.405.

Abstract

Excessive intake of trans-fatty acids increases the risk of cardiovascular disease. Much attention is drawn to the consumption of trans-fatty acids worldwide, and regulations for trans-fatty acids are instituted in several countries. Precise and convenient methods for determination of trans-fatty acid level are required, but there is no standard method using capillary Gas Chromatography in Japan. Therefore, for the new standard method, collaborative studies were carried out. The results were as follows: 1) Heptadecanoate (C17:0 free fatty acid) was chosen for internal standard substance. 2) Two Gas Chromatography columns, SP2560 (100 m) column (100% cyanopropyl polysiloxane liquid phase) and TC-70 (60 m) column (70% cyanopropyl polysilphenylene-siloxane liquid phase), were examined in the collaborative studies. We measured the edible oil samples containing 2-45 g/100 g of trans-fatty acids, and trans-fatty acid contents were quantitatively the same with both columns. The range of reproducibility coefficient of variation were below 10%. 3) Fats and oils sampled were soybean, rapeseed, palm, palm kernel, beef tallow, pork fat and their hydrogenated forms, for which good peak resolution was achieved. From the above results, the technique evaluated in the present study was considered to be suitable for determination of the content of trans-fatty acids in fats and oils exclusive of fish oil and milk fat.

摘要

过量摄入反式脂肪酸会增加心血管疾病的风险。反式脂肪酸的消费在全球范围内备受关注,一些国家制定了反式脂肪酸的相关规定。需要精确且便捷的方法来测定反式脂肪酸水平,但在日本尚无使用毛细管气相色谱法的标准方法。因此,针对新的标准方法开展了协同研究。结果如下:1)选择十七烷酸(C17:0游离脂肪酸)作为内标物质。2)在协同研究中考察了两根气相色谱柱,SP2560(100 m)柱(100%氰丙基聚硅氧烷液相)和TC - 70(60 m)柱(70%氰丙基聚苯基硅氧烷液相)。我们测定了反式脂肪酸含量为2 - 45 g/100 g的食用油样品,两根柱子对反式脂肪酸含量的定量结果相同。重现性变异系数范围低于10%。3)所采集的油脂包括大豆油、菜籽油、棕榈油、棕榈仁油、牛脂、猪脂及其氢化形式,均实现了良好的峰分离。基于上述结果,本研究中评估的技术被认为适用于测定除鱼油和乳脂外的油脂中反式脂肪酸的含量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验