Suppr超能文献

[穿透性角膜移植联合角膜基质内环植入。一项前瞻性随机研究]

[Penetrating keratoplasty with intrastromal corneal ring. A prospective randomized study].

作者信息

Birnbaum F, Schwartzkopff J, Böhringer D, Reinhard T

机构信息

Universitäts-Augenklinik Freiburg, Killianstrasse 5, 79106 Freiburg.

出版信息

Ophthalmologe. 2008 May;105(5):452-6. doi: 10.1007/s00347-007-1623-9.

Abstract

BACKGROUND

The purpose of the study was to evaluate the efficacy and safety of Krumeichs' intrastromal corneal ring following penetrating keratoplasty. Postoperative astigmatism and occurrence of complications were the main criteria of this study.

MATERIAL AND METHODS

A total of 20 patients were included in this prospectively randomized study (10 patients with and 10 patients without corneal ring). Follow-up examinations were performed 6 weeks, 4, 12, and 18 months postoperatively, including best corrected visual acuity and Orbscan corneal topography.

RESULTS

The mean follow-up time is currently 18.9+/-2.8 months. The mean astigmatism (Orbscan) is 3.9 D in the group with ring and 4.0 D in the group without a ring. Spontaneous suture rupture occurred in five patients with corneal ring.

CONCLUSIONS

The use of the intrastromal corneal ring following penetrating keratoplasty caused no reduction of postoperative astigmatism. The reason for the spontaneous suture ruptures is unclear.

摘要

背景

本研究的目的是评估穿透性角膜移植术后使用克鲁梅希基质内角膜环的有效性和安全性。术后散光和并发症的发生是本研究的主要标准。

材料与方法

本前瞻性随机研究共纳入20例患者(10例使用角膜环,10例未使用角膜环)。术后6周、4个月、12个月和18个月进行随访检查,包括最佳矫正视力和Orbscan角膜地形图检查。

结果

目前平均随访时间为18.9±2.8个月。使用角膜环组的平均散光(Orbscan测量)为3.9 D,未使用角膜环组为4.0 D。5例使用角膜环的患者发生了自发性缝线断裂。

结论

穿透性角膜移植术后使用基质内角膜环并未减少术后散光。自发性缝线断裂的原因尚不清楚。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验