Suppr超能文献

医疗废物焚烧炉废气和残渣中指示微生物测定方法的建立与评价

Development and evaluation of a method to determine indicator microorganisms in air emissions and residue from medical waste incinerators.

作者信息

Segall R R, Blanschan G C, DeWees W G, Hendry K M, Leese K E, Williams L G, Curtis F, Shigara R T, Romesberg L J

机构信息

Entropy Environmentalists, Inc. Research Triangle Park, North Carolina.

出版信息

J Air Waste Manage Assoc. 1991 Nov;41(11):1454-60. doi: 10.1080/10473289.1991.10466943.

Abstract

To allow testing of microbial destruction in medical waste incinerators, methods were developed to determine indicator microorganisms (Bacillus Stearothermophilus spores) in incinerator air emissions and residue. The emission trapping train consisted of a water cooled glass probe and impingers containing a neutral phosphate buffer. In field tests, spores were injected directly into the probe, and results showed that approximately 60 percent of the spores were recovered. Spores were analyzed with adequate precision using a microbial membrane filter unit. Lab experiments indicated that spores were stable in neutral pH phosphate buffer for up to 20 days, and heat shocking samples (heating to 80 degrees C for 20 minutes) reduced spore numbers in acidic or basic buffer. Laboratory tests also showed that 60 to 70 percent of spores initially added to ash were recovered up to 22 days after addition of the spores. In addition, lab tests showed that spores can be effectively recovered from residue test pipes spiked with indicator spores.

摘要

为了能够对医疗废物焚烧炉中的微生物破坏情况进行测试,人们开发了一些方法来测定焚烧炉废气排放物和残渣中的指示微生物(嗜热脂肪芽孢杆菌孢子)。废气捕集装置由一个水冷玻璃探头和装有中性磷酸盐缓冲液的冲击式吸收管组成。在现场测试中,将孢子直接注入探头,结果显示约60%的孢子能够被回收。使用微生物膜过滤装置对孢子进行分析具有足够的精度。实验室实验表明,孢子在中性pH值的磷酸盐缓冲液中可稳定存在长达20天,对样品进行热激处理(加热至80摄氏度20分钟)会使酸性或碱性缓冲液中的孢子数量减少。实验室测试还表明,最初添加到灰烬中的孢子,在添加后长达22天的时间里,有60%至70%能够被回收。此外,实验室测试表明,从添加了指示孢子的残渣测试管中能够有效地回收孢子。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验