Suppr超能文献

男性和女性热触觉与振动触觉阈值的正常值。

Normal values for thermotactile and vibrotactile thresholds in males and females.

作者信息

Seah Sue Ann, Griffin Michael J

机构信息

Human Factors Research Unit, Institute of Sound and Vibration Research, University of Southampton, Southampton, UK.

出版信息

Int Arch Occup Environ Health. 2008 Apr;81(5):535-43. doi: 10.1007/s00420-007-0252-6. Epub 2007 Sep 28.

Abstract

OBJECTIVES

This study was undertaken to compare normal values of thermotactile and vibrotactile thresholds in males and females and in younger and older age groups. In addition, for thermal thresholds, the effects of the contact area (small and large) and stimulus location (glabrous and non-glabrous skin) were investigated.

METHOD

Eighty healthy subjects participated in the study: 20 males and 20 females aged 20-30 years, and 20 males and 20 females aged 55-65 years. Subjects attended one 45 min experimental session consisting of acclimatisation for 10 min followed by 35 min of testing. Using the method of limits, hot thresholds and cold thresholds were measured on the non-dominant upper limb at three locations (the distal phalanx of the middle finger, the thenar eminence, and the dorsal surface of the forearm) using two circular contactors 1.0 and 2.8 cm in diameter. Using the von Békésy method, vibrotactile thresholds at 31.5 and 125 Hz were measured on the distal phalanx of the middle finger of the non-dominant hand.

RESULTS

Among the younger subjects there were significant gender differences in thermotactile thresholds but not vibrotactile thresholds. Age did not have any significant effect on thermotactile or vibrotactile thresholds. Hot thresholds were significantly higher and cold thresholds significantly lower when the larger stimulus area was used. The thresholds exceeded by 18% of the population (the mean plus one standard deviation) and by 2.5% (the mean plus two standard deviations) are provided and may be used to consider whether measured thresholds are within a "normal" range.

CONCLUSIONS

For males and females the same ranges of normal values may be used for vibrotactile thresholds but different ranges of normal values may be required for thermotactile thresholds. An age correction may not be needed for thermotactile or vibrotactile thresholds in persons aged 20-65 years. Contact area has an influence on thermotactile thresholds and should be controlled.

摘要

目的

本研究旨在比较男性和女性以及年轻和老年群体的热触觉和振动触觉阈值的正常值。此外,对于热阈值,研究了接触面积(小和大)和刺激部位(无毛和有毛皮肤)的影响。

方法

80名健康受试者参与了该研究:20名年龄在20 - 30岁的男性和20名女性,以及20名年龄在55 - 65岁的男性和20名女性。受试者参加一次45分钟的实验,包括10分钟的适应期,随后是35分钟的测试。使用极限法,在非优势上肢的三个部位(中指远端指骨、鱼际隆起和前臂背面)使用直径为1.0和2.8厘米的两个圆形接触器测量热阈值和冷阈值。使用冯·贝凯西方法,在非优势手的中指远端指骨上测量31.5和125赫兹的振动触觉阈值。

结果

在较年轻的受试者中,热触觉阈值存在显著的性别差异,但振动触觉阈值没有。年龄对热触觉或振动触觉阈值没有任何显著影响。当使用较大的刺激面积时,热阈值显著更高,冷阈值显著更低。提供了超过人群18%(平均值加一个标准差)和2.5%(平均值加两个标准差)的阈值,可用于判断测量的阈值是否在“正常”范围内。

结论

对于男性和女性,振动触觉阈值可使用相同的正常范围值,但热触觉阈值可能需要不同的正常范围值。对于20 - 65岁的人,热触觉或振动触觉阈值可能不需要进行年龄校正。接触面积对热触觉阈值有影响,应加以控制。