Lee Joong-Myung, Lee Churl-Woo
Department of Orthopaedic Surgery, National Medical Center, Seoul, Republic of Korea.
J Arthroplasty. 2007 Oct;22(7):1019-23. doi: 10.1016/j.arth.2007.04.029.
The comparison between standard blasted and hydroxyapatite (HA)-coated cementless femoral stems (CLS stem) was made in the same patients who have bilateral late-stage osteonecrosis. Clinical and radiographic evaluations were performed in 20 patients (among 29 patients) with the minimum follow-up of 10 years (range, 123-168 months). Endosteal bone formation was found in all patients of both stems, and no radiolucent line was observed. The mean of initial stem subsidence was 1.27 +/- 0.95 mm with the standard stem and 0.59 +/- 0.56 mm with the HA-coated stem. Other results, such as hip score, endosteal bone formation, cortical hypertrophy, osteolysis, and heterotopic ossification showed no statistical differences. These have suggested that the fixation obtained by the cementless stem with a corundum-blasted surface is stable enough to get excellent clinical and radiographic results without the HA coating.
在患有双侧晚期骨坏死的同一组患者中,对标准喷砂处理的股骨柄与羟基磷灰石(HA)涂层非骨水泥型股骨柄(CLS柄)进行了比较。对20例患者(共29例患者)进行了临床和影像学评估,最短随访时间为10年(范围为123 - 168个月)。在两种柄的所有患者中均发现骨内膜骨形成,且未观察到透亮线。标准柄的初始柄下沉平均值为1.27±0.95 mm,HA涂层柄为0.59±0.56 mm。其他结果,如髋关节评分、骨内膜骨形成、皮质肥大、骨溶解和异位骨化,均无统计学差异。这表明,具有刚玉喷砂表面的非骨水泥柄所获得的固定足够稳定,无需HA涂层即可获得优异的临床和影像学结果。