Kamphorst Jurre J, van der Heijden Rob, DeGroot Jeroen, Lafeber Floris P J G, Reijmers Theo H, van El Benno, Tjaden Ubbo R, van der Greef Jan, Hankemeier Thomas
Division of Analytical Biosciences, LACDR, Leiden University, P.O. Box 9502, 2300 RA Leiden, the Netherlands.
J Proteome Res. 2007 Nov;6(11):4388-96. doi: 10.1021/pr0704534. Epub 2007 Oct 11.
Synovial fluid potentially contains markers for early diagnosis and disease progression in degenerative joint diseases such as osteoarthritis. Here, a method is described for profiling endogenous peptides in human synovial fluid, using ultrafiltration, solid-phase extraction, nanoscale liquid chromatography, and high-resolution mass spectrometry. Synovial fluid is characterized by its high viscosity, caused by the presence of the lubricant hyaluronic acid. The method proved to be capable of eliminating the high concentrations of hyaluronic acid, which appeared to be necessary to obtain satisfactory analytical performance, that is, within-day relative standard deviations of 5-15%, between-day relative standard deviations of 6-16%, a linear response of R2=0.994, a limit of detection in the femtomole range, and reproducible recoveries of 14-67%. With the developed method, in a synovial fluid sample from an osteoarthritis patient and a healthy control, in total, 501 peptides originating from 40 proteins were identified. Peptide cleavage products from six proteins that have been associated with osteoarthritis in earlier studies (collagen II, proteoglcycan 4, serum amyloid A, tubulin, vimentin, and Matrix Gla) could also be identified with our profiling method. The robustness of the method indicates that it can be applied in systems biology approaches for further studies on degenerative joint disease, eventually leading to a better understanding of the disease and its therapy, as well as the development of novel biomarkers to monitor these processes.
滑液可能含有用于退行性关节疾病(如骨关节炎)早期诊断和疾病进展的标志物。本文描述了一种使用超滤、固相萃取、纳米级液相色谱和高分辨率质谱分析人滑液中内源性肽的方法。滑液的特征在于其因存在润滑剂透明质酸而具有高粘度。该方法被证明能够去除高浓度的透明质酸,而这似乎是获得令人满意的分析性能所必需的,即日内相对标准偏差为5 - 15%,日间相对标准偏差为6 - 16%,线性响应R2 = 0.994,飞摩尔范围内的检测限,以及14 - 67%的可重现回收率。使用该方法,在一名骨关节炎患者和一名健康对照的滑液样本中,总共鉴定出了来自40种蛋白质的501种肽。在早期研究中与骨关节炎相关的六种蛋白质(胶原蛋白II、蛋白聚糖4、血清淀粉样蛋白A、微管蛋白、波形蛋白和基质Gla蛋白)的肽裂解产物也可以通过我们的分析方法鉴定出来。该方法的稳健性表明,它可应用于系统生物学方法,以进一步研究退行性关节疾病,最终更好地理解该疾病及其治疗方法,以及开发用于监测这些过程的新型生物标志物。